Evidence map›Paper›PMID 32549396›Full record

ArticleSensors (Basel, Switzerland)2020

A Multiday Evaluation of Real-Time Intramuscular EMG Usability with ANN.

Asim Waris, Muhammad Zia Ur Rehman, Imran Khan Niazi, Mads Jochumsen, Kevin Englehart, Winnie Jensen, Heidi Haavik, Ernest Nlandu Kamavuako

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Asim WarisDepartment of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.ORCID 0000-0002-0190-0700
Muhammad Zia Ur RehmanFaculty of Engineering and Applied Sciences, Riphah International University, Islamabad 46000, Pakistan.ORCID 0000-0002-6141-3648
Imran Khan NiaziCenter for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.ORCID 0000-0001-8752-7224
Mads JochumsenCenter for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.ORCID 0000-0001-7729-4359
Kevin EnglehartDepartment of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB E3B 5A3, Canada.ORCID 0000-0003-4525-1121
Winnie JensenCenter for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.
Heidi HaavikCenter of Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand.
Ernest Nlandu KamavuakoCentre for Robotics Research, Department of Informatics, King's College London, London WC2R 2LS, UK.ORCID 0000-0001-6846-2090

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent developments in implantable technology, such as high-density recordings, wireless transmission of signals to a prosthetic hand, may pave the way for intramuscular electromyography (iEMG)-based myoelectric control in the future. This study aimed to investigate the real-time control performance of iEMG over time. A novel protocol was developed to quantify the robustness of the real-time performance parameters. Intramuscular wires were used to record EMG signals, which were kept inside the muscles for five consecutive days. Tests were performed on multiple days using Fitts' law. Throughput, completion rate, path efficiency and overshoot were evaluated as performance metrics using three train/test strategies. Each train/test scheme was categorized on the basis of data quantity and the time difference between training and testing data. An artificial neural network (ANN) classifier was trained and tested on (i) data from the same day (WDT), (ii) data collected from the previous day and tested on present-day (BDT) and (iii) trained on all previous days including the present day and tested on present-day (CDT). It was found that the completion rate (91.6 ± 3.6%) of CDT was significantly better (

Indexed as

Pattern Recognition, AutomatedElectrodesElectromyographyHumansMuscle, SkeletalNeural Networks, Computerintramuscular electromyography (iEMG)pattern recognition (PR)prosthetic hand

Identifiers

PMID32549396
PMCPMC7349229

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.