ArticleSensors (Basel, Switzerland)2020
Data Description Technique-Based Islanding Classification for Single-Phase Grid-Connected Photovoltaic System.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
This paper develops an islanding classification mechanism to overcome the problems of non-detection zones in conventional islanding detection mechanisms. This process is achieved by adapting the support vector-based data description technique with Gaussian radial basis function kernels for islanding and non-islanding events in single phase grid-connected photovoltaic (PV) systems. To overcome the non-detection zone, excess and deficit power imbalance conditions are considered for different loading conditions. These imbalances are characterized by the voltage dip scenario and were subjected to feature extraction for training with the machine learning technique. This is experimentally realized by training the machine learning classifier with different events on a 5 kW grid-connected system. Using the concept of detection and false alarm rates, the performance of the trained classifier is tested for multiple faults and power imbalance conditions. The results showed the effective operation of the classifier with a detection rate of 99.2% and a false alarm rate of 0.2%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.