Evidence map›Paper›PMID 32542676›Full record

SynthesisThe Cochrane database of systematic reviews2020

Ventriculo-peritoneal shunting devices for hydrocephalus.

Luis Garegnani, Juan Va Franco, Agustín Ciapponi, Virginia Garrote, Valeria Vietto, Santiago Adalberto Portillo Medina

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. The application of programmable shunts in the management of hydrocephalus in pediatric patients.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
    Article
  4. Short-term clinical outcomes of changing CSF shunt valve type or shunt valve brand in revision surgeries for the management of pediatric hydrocephalus.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Analysis of non-ventriculoperitoneal shunts at Red Cross War Memorial Children's Hospital.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2024
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Review
  17. Article
  18. Shunt technology for infants and a lifetime.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2021
    Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luis GaregnaniResearch Department, Instituto Universitario Hospital Italiano, Buenos Aires, Argentina.
Juan Va FrancoArgentine Cochrane Centre, Instituto Universitario Hospital Italiano, Buenos Aires, Argentina.
Agustín CiapponiArgentine Cochrane Centre, Institute for Clinical Effectiveness and Health Policy (IECS-CONICET), Buenos Aires, Argentina.
Virginia GarroteBiblioteca Central, Instituto Universitario Hospital Italiano, Buenos Aires, Argentina.
Valeria ViettoFamily and Community Medicine Service, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
Santiago Adalberto Portillo MedinaPediatric Neurosurgery Service, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHydrocephalus is a common neurological disorder, caused by a progressive accumulation of cerebrospinal fluid (CSF) within the intracranial space that can lead to increased intracranial pressure, enlargement of the ventricles (ventriculomegaly) and, consequently, to brain damage. Ventriculo-peritoneal shunt systems are the mainstay therapy for this condition, however there are different types of shunt systems.

objectivesTo compare the effectiveness and adverse effects of conventional and complex shunt devices for CSF diversion in people with hydrocephalus. SEARCH

methodsWe searched the Cochrane Central Register of Controlled Trials (2020 Issue 2); Ovid MEDLINE (1946 to February 2020); Embase (Elsevier) (1974 to February 2020); Latin American and Caribbean Health Science Information Database (LILACS) (1980 to February 2020); ClinicalTrials.gov; and World Health Organization International Clinical Trials Registry Platform. SELECTION CRITERIA: We selected randomised controlled trials or quasi-randomised trials of different types of ventriculo-peritoneal shunting devices for people with hydrocephalus. Primary outcomes included: treatment failure, adverse events and mortality. DATA COLLECTION AND ANALYSIS: Two review authors screened studies for selection, assessed risk of bias and extracted data. Due to the scarcity of data, we performed a Synthesis Without Meta-analysis (SWiM) incorporating GRADE for the quality of the evidence. MAIN

resultsWe included six studies with 962 participants assessing the effects of standard valves compared to anti-syphon valves, other types of standard valves, self-adjusting CSF flow-regulating valves and external differential programmable pressure valves. All included studies started in a hospital setting and offered ambulatory follow-up. Most studies were conducted in infants or children with hydrocephalus from diverse causes. The certainty of the evidence for most comparisons was low to very low. 1. Standard valve versus anti-syphon valve Three studies with 296 randomised participants were included under this comparison. We are uncertain about the incidence of treatment failure in participants with standard valve and anti-syphon valves (very low certainty of the evidence). The incidence of adverse events may be similar in those with standard valves (range 0 to 1.9%) and anti-syphon valves (range 0 to 2.9%) (low certainty of the evidence). Mortality may be similar in those with standard valves (0%) and anti-syphon valves (0.9%) (RD 0.01%, 95% CI -0.02% to 0.03%, low certainty of the evidence). Ventricular size and head circumference may be similar in those with standard valves and anti-syphon valves (low certainty of the evidence). None of the included studies reported the quality of life of participants. 2. Comparison between different types of standard valves Two studies with 174 randomised participants were included under this comparison. We are uncertain about the incidence of treatment failure in participants with different types of standard valves (early postoperative period: RR 0.41, 95% CI 0.13 to 1.27; at 12 months follow-up: RR 1.17, 95% CI 0.72 to 1.92, very low certainty of the evidence). None of the included studies reported adverse events beyond those included under "treatment failure". We are uncertain about the effects of different types of standard valves on mortality (range 2% to 17%, very low certainty of the evidence). The included studies did not report the effects of these interventions on quality of life, ventricular size reduction or head circumference. 3. Standard valve versus self-adjusting CSF flow-regulating valve One study with 229 randomised participants addressed this comparison. The incidence of treatment failure may be similar in those with standard valves (42.98%) and self-adjusting CSF flow-regulating valves (39.13%) (low certainty of the evidence). The incidence of adverse events may be similar in those with standard valves (range 0 to 1.9%) and those with self-adjusting CSF flow-regulating valves (range 0 to 7.2%) (low certainty of the evidence). The included study reported no deaths in either group in the postoperative period. Beyond the early postoperative period, the authors stated that nine patients died (no disaggregated data by each type of intervention was available, low certainty of the evidence). The included studies did not report the effects of these interventions on quality of life, ventricular size reduction or head circumference. 4. External differential programmable pressure valve versus non-programmable valve One study with 377 randomised participants addressed this comparison. The incidence of treatment failure may be similar in those with programmable valves (52%) and non-programmable valves (52%)  (RR 1.02, 95% CI 0.84 to 1.24, low certainty of the evidence). The incidence of adverse events may be similar in those with programmable valves (6.19%) and non-programmable valves (6.01%) (RR 0.97, 95% CI 0.44 to 2.15, low certainty of the evidence). The included study did not report the effect of these interventions on mortality, quality of life or head circumference. Ventricular size reduction may be similar in those with programmable valves and non-programmable valves (low certainty of the evidence). AUTHORS'

conclusionsStandard shunt valves for hydrocephalus compared to anti-syphon or self-adjusting CSF flow-regulating valves may cause little to no difference on the main outcomes of this review, however we are very uncertain due to the low to very low certainty of evidence. Similarly, different types of standard valves and external differential programmable pressure valves versus non-programmable valves may be associated with similar outcomes. Nevertheless, this review did not include valves with the latest technology, for which we need high-quality randomised controlled trials focusing on patient-important outcomes including costs.

Indexed as

ChildEquipment DesignHumansHydrocephalusInfantMicrocomputersRandomized Controlled Trials as TopicTreatment FailureUncertaintyVentriculoperitoneal Shunt

Identifiers

PMID32542676
PMCPMC7388891

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.