ReviewDer Orthopade2020
[PSI-technique for kinematic alignment].
Review in Der Orthopade, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- [Patient-specific instrumentation in total knee arthroplasty - current concepts and clinical implications].Orthopadie (Heidelberg, Germany) · 2025Article
- High accuracy of a new robotically assisted technique for total knee arthroplasty: an in vivo study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCompared with the current gold standard of knee endoprosthetics, the concept of kinematic alignment is more responsive to the individual anatomy of the patient as it enables the three-dimensional restoration of individual axes, joint lines and capsule tension. One point of criticism is the lack of intraoperative control over individual bone resections with conventional instrumentation. However, with the help of CT-based individual 3D-printed cutting blocks, a precise preoperative plan can be transferred to the operating room. The aim of this article is to explain the operative technique of patient-specific instrumentation (PSI)-protected kinematic alignment.
methodsThe procedure is based on a preoperative 3D model of the bony anatomy of the patient, with the aid of which the planning of the operation, with the positioning and size of the implant, as well as the necessary bone resections, are carried out. With this information about anatomy and resection levels the individual cutting blocks are produced, aided by a 3D printer. Intraoperative control is achieved by measuring the resection by means of a gage and comparison with the digital 3D design. DISCUSSION: With the aid of the 3D-printed PSI cutting blocks the preoperative plan of kinematic alignment can be implemented in a precise manner. It is a simple tool and does not require any great expense. Compared with the conventional instrumentation, the operating time is shortened. However, because of the purely CT-based design, no information about the state of the soft tissue is obtained.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.