ArticleACS omega2020
Rapid Detection of IgM Antibodies against the SARS-CoV-2 Virus via Colloidal Gold Nanoparticle-Based Lateral-Flow Assay.
Article in ACS omega, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 170 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
170 citing papers in PubMed, 342 citations in OpenAlex.
- Surface-Enhanced Raman Spectroscopy for Viral Diagnostics: Principles, Strategies, Clinical Challenges, and Future Directions.Chemical reviews · 2026Review
- A Portable Colorimetric Device for Rapid Bacterial Detection with Cleavable Functional Nucleic Acid Probes for A Common Bacterial Endoribonuclease.Angewandte Chemie (International ed. in English) · 2026Article
- Development of a Lateral Flow Immunoassay Strips for Rapid Antigen Detection of Dabie bandavirus.ACS omega · 2025Article
- A Scoring Function for Monolayer-Protected Gold Nanoparticles Capable of Recognizing Small Organic Molecules in Solution.Journal of chemical theory and computation · 2025Article
- FePtCoNiCu High-Entropy Nanozymes Embedded in a Hydrogel Matrix as a Portable, Rapid, and Visual On-Site Biosensing Platform.Analytical chemistry · 2025Article
- Covalently Oriented AuNP-Antibody Bioconjugates Enable Early and Sensitive Detection ofACS omega · 2025Article
- Comprehensive and translational pathobiology of COVID-19 based on cellular and molecular techniques.Practical laboratory medicine · 2025Review
- Accelerated design of gold nanoparticles with enhanced plasmonic performance.Science advances · 2025Article
- Transformative biomedical devices to overcome biomatrix effects.Biosensors & bioelectronics · 2025Review
- Development of a colloidal gold immunochromatographic strip to detect equine infectious anemia virus.Virology journal · 2025Article
- Innovation landscape in nanobiosensors for COVID-19 detection and future implications for a resilient Global Health Security.3 Biotech · 2025Review
- Emerging Trends of Gold Nanostructures for Point-of-Care Biosensor-Based Detection of COVID-19.Molecular biotechnology · 2025Review
- Gold Nanoparticles as a Tool to Detect Biomarkers in Osteoarthritis: New Insights.Indian journal of microbiology · 2025Article
- SARS-CoV-2 neutralizing antibody determination after vaccination using spectrophotometric measurement of lateral flow immunochromatography.Scientific reports · 2025Article
- Advancements in nanobiosensor technologies for in-vitro diagnostics to point of care testing.Heliyon · 2024Review
- A fluorescence-based lateral flow immunoassay using AIEgen-encapsulated nanoparticles to rapidly and sensitively detect pro-gastrin-releasing peptide.Mikrochimica acta · 2024Article
- The evolution of immune profiling: will there be a role for nanoparticles?Nanoscale horizons · 2024Review
- Optofluidic chip with directly printed polymer optical waveguide Mach-Zehnder interferometer sensors for label-free biodetection.Biomedical optics express · 2024Article
- Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors.Biosensors · 2024Review
- Article
110 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Last year, the novel coronavirus disease (COVID-19) emerged in Wuhan, and it has rapidly spread to many other countries and regions. COVID-19 exhibits a strong human-to-human transmission infectivity and could cause acute respiratory diseases. Asymptomatic carriers are able to infect other healthy persons, and this poses a challenge for public health; the World Health Organization (WHO) has already announced COVID-19 as a global pandemic. Nucleic acid testing, considered as the current primary method for diagnosing COVID-19, might lead to false negatives and is difficult to be applied for every suspected patient because of the existence of asymptomatic carriers. Meanwhile, detecting specific antibodies in blood, such as the IgM antibody, against the SARS-CoV-2 virus is another choice for COVID-19 diagnosis, as it is widely accepted that IgM is an important indicator in the acute infection period. In this study, a colloidal gold nanoparticle-based lateral-flow (AuNP-LF) assay was developed to achieve rapid diagnosis and on-site detection of the IgM antibody against the SARS-CoV-2 virus through the indirect immunochromatography method. For preparing AuNP-LF strips, the SARS-CoV-2 nucleoprotein (SARS-CoV-2 NP) was coated on an analytical membrane for sample capture, and antihuman IgM was conjugated with AuNPs to form the detecting reporter. Optimization of AuNP-LF assay was carried out by altering the pH value and the amount of antihuman IgM. The performance of AuNP-LF assay was evaluated by testing serum samples of COVID-19 patients and normal humans. The results were compared with the real-time polymerase chain reaction. The sensitivity and specificity of AuNP-LF assay were determined to be 100 and 93.3%, respectively, and an almost perfect agreement was exhibited by Kappa statistics (κ coefficient = 0.872). AuNP-LF assay showed outstanding selectivity in the detection of IgM against the SARS-CoV-2 virus with no interference from other viruses such as severe fever with thrombocytopenia syndrome virus (SFTSV) and dengue virus (DFV). AuNP-LF assay was able to achieve results within 15 min and needed only 10-20 μL serum for each test. As a whole, in the light of its advantages such as excellent specificity and stability, easy operation, low cost, and being less time-consuming, AuNP-LF assay is a feasible method for the diagnosis of COVID-19 in primary hospitals and laboratories, especially in emergency situations in which numerous samples need to be tested on time.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.