In one paragraph

Article in Skeletal radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.2field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sebastian TschaunerDivision of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria. sebastian.tschauner@medunigraz.at.ORCID http://orcid.org/0000-0002-7873-9839
Robert MartererDivision of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
Eszter NagyDivision of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
Georg SingerDepartment of Paediatric and Adolescent Surgery, Medical University of Graz, Auenbruggerplatz 34, Graz, 8036, Austria.
Michael RiccabonaDivision of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
Erich SorantinDivision of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
Medical University of Graz · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionNovel dedicated extremity cone beam computed tomography (CBCT) devices, recently introduced to the market, raised attention as a possible alternative in advanced diagnostic pediatric trauma imaging, today usually performed by multidetector computed tomography (MDCT). This work aimed to compare image quality and radiation dose of CBCT and MDCT. MATERIALS AND

methodsFifty-four CBCT-MDCT examination pairs, containing nine MDCTs acquired in parallel prospectively and 45 MDCTs matched in retrospect, were included in this study. Image quality was analyzed semi-objectively by measuring noise, contrast-to-noise ratio (CNR), and signal-to-noise ratios (SNR) and subjectively by performing image impression ratings. CT dose records were readout.

resultsImage noise was significantly lower in CBCT compared with MDCT, both semi-objectively and subjectively (both p < 0.001). CNR and SNRs were also in favor of CBCT, though CBCT examinations exhibited significantly more beam hardening artifacts that diminished the advantages of the superior semi-objective image quality. These artifacts were believed to occur more often in children due to numerous bone-cartilage transitions in open growth plates and may have led to a better subjective diagnostic certainty rating (p = 0.001). Motion artifacts were infrequently, but exclusively observed in CBCT. CT dose index (CTDI

conclusionDedicated extremity CBCT could be an alternative low-dose modality in the diagnostic pathway of pediatric fractures. At lower doses compared with MDCT and commonly affected by beam hardening artifacts, semi-objective CBCT image quality parameters were generally better than in MDCT.

Indexed as

Multidetector Computed TomographySpiral Cone-Beam Computed TomographyChildCone-Beam Computed TomographyExtremitiesHumansPhantoms, ImagingRadiation DosageChildCone-beam computed tomographyHumansMultidetector computed tomographyMusculoskeletal diseases

Identifiers

PMID32535775
PMCPMC7652807
OpenAlexW3035072999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.