ArticleNeuroradiology2020
Intrathecal use of gadobutrol for gadolinium-enhanced MR cisternography in the evaluation of patients with otorhinorrhea.
Article in Neuroradiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- Relaxivity of Gadobutrol and Gadoteric Acid in Cerebrospinal Fluid at 3T.Magnetic resonance in medicine · 2026Article
- Exploratory operation in a patient with spontaneous temporal bone cerebrospinal fluid leaks: A case report.World journal of clinical cases · 2025Article
- Gadolinium-based MR cisternography with prepontine cisternal routine for evaluating distribution pattern of intrathecal targeted drug delivery in pain management.Drug delivery · 2023Article
- Intrathecal [Scientific reports · 2023Article
- Feasibility of 3D T1W sequences in contrast-material enhanced MR cisternography at 3T.Turkish journal of medical sciences · 2022Article
- Telemedicine in Surgical Care in Low- and Middle-Income Countries: A Scoping Review.World journal of surgery · 2022Article
- Quantifying cerebrospinal fluid dynamics: A review of human neuroimaging contributions to CSF physiology and neurodegenerative disease.Neurobiology of disease · 2022Review
- Surgical Repair of Skull Base CSF Leaks after Cisternography Diagnosis: Analysis of Validity and Surgical Outcome and Impact on Future Treatment Strategies.BioMed research international · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIntrathecal gadolinium-enhanced MR cisternography (IGE-MRC) has a high sensitivity to detect accurate localization of cerebrospinal fluid (CSF) leakage in otorhinorrhea patients. Our purpose in this study was to describe our experience in analyzing clinically suspected CSF leakage by IGE-MRC by using gadobutrol with emphasis on its safety and diagnostic performance.
methodsWe retrospectively reviewed our imaging and clinical database for the evaluation of patients admitted to our clinic with complaints of otorhinorrhea between 2017 and 2019. Two radiologists evaluated the imaging studies independently. Consensus data was used in the analysis. Medical record review and phone call were used for the follow-up.
resultsOf the 85 patients included in the retrospective analysis, 82 (96.5%) had rhinorrhea and 3 (3.5%) had otorrhea. Overall, 29 patients (34.1% of all patients) underwent operation for repair of the CSF leakage site. Beta-transferrin test was available and positive in 33 patients (38.8%). Five (5.9%) patients complained headaches after the procedure and complaints were resolved with increased water intake. Postprocedurally, 3 patients (3.5%) had vertigo and 1 patient (1.2%) complained nausea but spontaneous regression were observed in a few hours. None of the patients experienced a significant complication or adverse reaction during follow-up period. Sixty-seven patients (78.8%) had medical record and telephone follow-up. Mean follow-up duration with call was 14.2 months.
conclusionIGE-MRC is a minimally invasive and highly sensitive imaging technique. The current results during our follow-up demonstrate the relative safety and feasibility of IGE-MRC by using gadobutrol to evaluate CSF leakage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.