Field camera versus phantom-based measurement of the gradient system transfer function (GSTF) with dwell time compensation.

M Stich, J A J Richter, T Wech, T A Bley, R Ringler, H Köstler, A E Campbell-Washburn

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

M StichDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany; Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, USA; X-Ray & Molecular Imaging Lab, Technical University Amberg-Weiden, Germany. Electronic address: manuel_stich@gmx.de.
J A J RichterDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany; Comprehensive Heart Failure Center Würzburg, Würzburg, Germany.
T WechDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
T A BleyDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
R RinglerX-Ray & Molecular Imaging Lab, Technical University Amberg-Weiden, Germany.
H KöstlerDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
A E Campbell-WashburnCardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, USA.
Universitätsklinikum Würzburg · DEOstbayerische Technische Hochschule Amberg-Weiden · DENational Heart Lung and Blood Institute · US

Funding

Gadgetron Global Network and Intelligence Computing: Clinical Imaging Application Development and Software InfrastructureZIAHL006214 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI KELLMAN, PETER · 2016 to 2025
$7.3M
Innovative Technology for MRI Guided ProceduresZIAHL006213 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2016 to 2025
$5.4M
Intramural NIH HHS ZIA HL006214
6 · The paper itself

Abstract

purposeThe gradient system transfer function (GSTF) can be used to describe the dynamic gradient system and applied for trajectory correction in non-Cartesian MRI. This study compares the field camera and the phantom-based methods to measure the GSTF and implements a compensation for the difference in measurement dwell time.

methodsThe self-term GSTFs of a MR system were determined with two approaches: 1) using a dynamic field camera and 2) using a spherical phantom-based measurement with standard MR hardware. The phantom-based GSTF was convolved with a box function to compensate for the dwell time dependence of the measurement. The field camera and phantom-based GSTFs were used for trajectory prediction during retrospective image reconstruction of 3D wave-CAIPI phantom images.

resultsDifferences in the GSTF magnitude response were observed between the two measurement methods. For the wave-CAIPI sequence, this led to deviations in the GSTF predicted trajectories of 4% compared to measured trajectories, and residual distortions in the reconstructed phantom images generated with the phantom-based GSTF. Following dwell-time compensation, deviations in the GSTF magnitudes, GSTF-predicted trajectories, and resulting image artifacts were eliminated (< 0.5% deviation in trajectories).

conclusionWith dwell time compensation, both the field camera and the phantom-based GSTF self-terms show negligible deviations and lead to strong artifact reduction when they are used for trajectory correction in image reconstruction.

Indexed as

Phantoms, ImagingAlgorithmsArtifactsHumansImaging, Three-DimensionalMagnetic Resonance ImagingRetrospective StudiesDwell time compensationField cameraGradient impulse response functionGradient system transfer functionTrajectory correctionWave Wave-CAIPI imaging

Identifiers

PMID32534067
PMCPMC7654095
OpenAlexW3035466808

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.