Evidence map›Paper›PMID 32533758›Full record

ArticleJournal of applied clinical medical physics2020

Investigation of tumor and vessel motion correlation in the liver.

Sydney A Jupitz, Andrew J Shepard, Patrick M Hill, Bryan P Bednarz

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sydney A JupitzDepartment of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.ORCID https://orcid.org/0000-0001-9104-8920
Andrew J ShepardDepartment of Human Oncology, University of Wisconsin-Madison, Madison, WI, USA.ORCID https://orcid.org/0000-0001-5299-5888
Patrick M HillDepartment of Human Oncology, University of Wisconsin-Madison, Madison, WI, USA.ORCID https://orcid.org/0000-0002-1208-0568
Bryan P BednarzDepartment of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.ORCID https://orcid.org/0000-0002-7467-9816
University of Wisconsin–Madison · US

Funding

Real-time Tumor Localization and Guidance for Radiotherapy Using US and MRIR01CA190298 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI BEDNARZ, BRYAN PATRICK, FOO, THOMAS K · 2015 to 2019
$3.1M
NIH HHS R01CA190298
6 · The paper itself

Abstract

Intrafraction imaging-based motion management systems for external beam radiotherapy can rely on internal surrogate structures when the target is not easily visualized. This work evaluated the validity of using liver vessels as internal surrogates for the estimation of liver tumor motion. Vessel and tumor motion were assessed using ten two-dimensional sagittal MR cine datasets collected on the ViewRay MRIdian. For each case, a liver tumor and at least one vessel were tracked for 175 s. A tracking approach utilizing block matching and multiple simultaneous templates was applied. Accuracy of the tracked motion was calculated from the error between the tracked centroid position and manually defined ground truth annotations. The patient's abdomen surface and diaphragm were manually annotated in all frames. The Pearson correlation coefficient (CC) was used to compare the motion of the features and tumor in the anterior-posterior (AP) and superior-inferior (SI) directions. The distance between the centroids of the features and the tumors was calculated to assess if feature proximity affects relative correlation, and the tumor range of motion was determined. Intra- and interfraction motion amplitude variabilities were evaluated to further assess the relationship between tumor and feature motion. The mean CC between the motion of the vessel and the tumor were 0.85 ± 0.11 (AP) and 0.92 ± 0.04 (SI), 0.83 ± 0.11 (AP) and -0.89 ± 0.06 (SI) for the surface and tumor, and 0.80 ± 0.17 (AP) and 0.94 ± 0.03 (SI) for the diaphragm and tumor. For intrafraction analysis, the average amplitude variability was 2.47 ± 0.77 mm (AP) and 3.14 ± 1.49 mm (SI) for the vessels, 2.70 ± 1.08 mm (AP) and 3.43 ± 1.73 mm (SI) for the surface, and 2.76 ± 1.41 mm (AP) and 2.91 ± 1.38 mm (SI) for the diaphragm. No relationship between distance and motion correlation was observed. The motion of liver tumors and liver vessels was well correlated, making vessels a suitable surrogate for tumor motion in the liver.

Indexed as

Liver NeoplasmsRespirationDiaphragmHumansMotionMovementbreathing motionIGRTlivermotion managementvessel tracking

Identifiers

PMID32533758
PMCPMC7484818
OpenAlexW3034793295

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.