Evidence map›Paper›PMID 32533222›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021

Lack of small tibial component size availability for females in a highly utilized total knee arthroplasty system.

Simon P Garceau, Paul A Enns, Greg M Teo, Aaron I Weinblatt, Vinay K Aggarwal, William J Long

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Simon P GarceauDivision of Orthopedics Surgery-Adult Joint Reconstruction, NYU Langone, 301 E 17th Street, suite 1402, New York, NY, 10003, USA.ORCID http://orcid.org/0000-0002-1043-8669
Paul A EnnsDivision of Orthopedics Surgery-Adult Joint Reconstruction, NYU Langone, 301 E 17th Street, suite 1402, New York, NY, 10003, USA.
Greg M TeoInsall-Scott-Kelly Institute, New York, NY, USA.
Aaron I WeinblattInsall-Scott-Kelly Institute, New York, NY, USA.
Vinay K AggarwalDivision of Orthopedics Surgery-Adult Joint Reconstruction, NYU Langone, 301 E 17th Street, suite 1402, New York, NY, 10003, USA.
William J LongDivision of Orthopedics Surgery-Adult Joint Reconstruction, NYU Langone, 301 E 17th Street, suite 1402, New York, NY, 10003, USA. william.long2@nyulangone.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSurgeons must rely on manufacturers to provide an appropriate distribution of total knee arthroplasty (TKA) sizes. There is a lack of literature regarding current appropriateness of tibial sizing schemes according to sex. As such, a study was devised assessing the adequacy of off-the-shelf tibial component size availability according to sex.

methodsA search was conducted to identify all primary TKAs between July 2012 and June 2019 performed using a single implant. Baseline patient characteristics were collected (age, weight, height, BMI, and race). Two cohorts were created according to patient sex. Tibial sizes for each cohort were collected. Tibial component bar graph and histogram were created according to component sizes. Skewness and kurtosis were calculated for each distribution. Overhang was noted and measured radiographically.

resultsA total of 864 patients were identified, 38.7% males and 61.3% females. Most patients were Caucasian, and BMI was similar between cohorts. Tibial size distribution for males was as follows: 0.3% C, 4.8% D, 16.5% E, 40.1% F, 31.4% G, 6.9% H. Tibial size distribution for females was as follows: 30.8% C, 42.8% D, 23.0% E, 2.6% F, 0.8% G, 0.0% H. Histograms and normal curves demonstrated a fairly symmetric distribution of sizes for males (skewness = - 0.31, kurtosis = - 0.03). The distribution for females was positively skewed (skewness = 0.57, kurtosis = 0.12). Overall, overhang was noted in 16.6% of all size C tibias.

conclusionsThe results of this study highlight an implant-specific discrepancy in size availability affecting female patients which could result in inferior outcomes. The authors urge manufacturers to critically assess current implant size distribution availability to ensure both genders are adequately, and equally represented. LEVEL OF EVIDENCE: IV.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisCohort StudiesFemaleHumansKnee JointMaleRetrospective StudiesTibiaDistributionGender biasSizing schemesTibial componentTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.