Evidence map›Paper›PMID 32532306›Full record

ArticleBMC musculoskeletal disorders2020

Reliability of two different measuring techniques with computer tomography for penetration and distribution of cement in the proximal tibia after total knee arthroplasty.

Hennie Verburg, Linda van Zeeland Koobs, Dieu Donné Niesten, Peter Pilot, Nina Mathijssen

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hennie VerburgDepartment of Orthopaedic Surgery, Reinier de Graaf Groep, Reinier de Graafweg 5, 2625, AD, Delft, The Netherlands. hverburg@rdgg.nl.ORCID http://orcid.org/0000-0001-6698-6958
Linda van Zeeland KoobsDepartment of Radiology, Reinier de Graaf Groep, Reinier de Graafweg 5, 2625, AD, Delft, The Netherlands.
Dieu Donné NiestenDepartment of Orthopaedic Surgery, Reinier de Graaf Groep, Reinier de Graafweg 5, 2625, AD, Delft, The Netherlands.
Peter PilotDepartment of Orthopaedic Research, Reinier de Graaf Groep, Reinier de Graafweg 5, 2625, AD, Delft, The Netherlands.
Nina MathijssenDepartment of Orthopaedic Research, Reinier de Graaf Groep, Reinier de Graafweg 5, 2625, AD, Delft, The Netherlands.
Reinier de Graaf Hospital · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo evaluate the reliability of two different techniques for measuring penetration and distribution of the cement mantle in the proximal tibia after total knee arthroplasty (TKA) with Computer Tomography (CT) in vivo.

methodsStandardized CT scans of the proximal tibia were taken 1 to 2 years after total knee arthroplasties implanted with a surface cementing technique. These prospectively acquired transversal CT images of the surface of the proximal tibia were divided into four quadrants and were assessed once manually and once with a numerical computing program (MATLAB® Update 2, The MathWorks, Inc.) based on Hounsfield Units by one of the researchers. The assessments were repeated by the same and a second researcher. The ratio cement/trabecular bone was calculated 1, 3 and 5 mm distal of the tibia tray per quadrant. Kruskall-Wallis tests with multiple pairwise comparisons (Dunn's test) were used to determine differences between the quadrants. Intra- and inter-rater reliability as well as the inter method reliability were assessed with the Intraclass Correlation Coefficient (ICC) per level of depth and with Bland-Altman plots.

resultsA total of 92 CT scans were included. The intra- and inter-rater reliability of the manual method ranged from 0.22 and 0.52. The intra- and inter-rater reliability of the matlab method varied between 0.98 to 0.99. The median percentage cement measured with the matlab method 1 mm underneath the tibial tray varied between 82 and 88%; at 3 mm depth between 38 and 54% and at 5 mm between 15 and 25%. There was significantly (p < 0.05) less cement in the antero-medial quadrant compared to the antero-lateral and postero-lateral quadrant at 3 mm and 5 mm depth.

conclusionsDistribution and penetration of cement in the proximal tibia in a total knee arthroplasty can be measured reliably with CT in combination with the matlab method presented in this manuscript. This method can be used for clinical purposes as well as for scientific research.

trial registrationMETC-nr: 06-104 Dossier NL14807.098.06/versie 06.

Indexed as

AgedArthroplasty, Replacement, KneeBone CementsCementationFemaleHumansMaleMiddle AgedNetherlandsProspective StudiesReproducibility of ResultsTibiaTomography, X-Ray ComputedBone CementsCement distributionCement penetrationComputer tomographyCT scanTKATotal knee Arthroplasty

Identifiers

PMID32532306
PMCPMC7291566
OpenAlexW3035586583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.