Evidence map›Paper›PMID 32530931›Full record

ArticlePloS one2020

Effects of pannus formation on the flow around a bileaflet mechanical heart valve.

Woojin Kim, Haecheon Choi, Jihoon Kweon, Dong Hyun Yang, Young-Hak Kim

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 100% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 0 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Woojin KimDepartment of Mechanical Engineering, Seoul National University, Seoul, Korea.
Haecheon ChoiDepartment of Mechanical Engineering, Seoul National University, Seoul, Korea.ORCID 0000-0003-0696-847X
Jihoon KweonDepartment of Cardiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
Dong Hyun YangDepartment of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.ORCID 0000-0001-5477-558X
Young-Hak KimDepartment of Cardiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
Ulsan College · KRSeoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Some patients with a bileaflet mechanical heart valve (BMHV) show significant increases in the transvalvular pressure drop and abnormal leaflet motion due to a pannus (an abnormal fibrovascular tissue) formed on the ventricular side, even in the absence of physical contact between the pannus and leaflets. We investigate the effects of the pannus shape (circular or semi-circular ring), implantation location and height on the leaflet motion, flow structure and transvalvular pressure drop using numerical simulations. The valve model considered resembles a 25 mm masters HP valve. The mean systolic pressure drop is significantly increased with increasing pannus height, irrespective of its implantation orientation. Near the peak inflow rate, the flow behind the pannus becomes highly turbulent, and the transvalvular pressure drop is markedly increased by the pannus. At the end of valve opening and the start of valve closing, oscillatory motions of the leaflets occur due to periodic shedding of vortex rings behind the pannus, and their amplitudes become large with increasing pannus height. When the pannus shape is asymmetric (e.g., a semi-circular ring) and its height reaches about 0.1D (D (= 25 mm) is the diameter of an aorta), abnormal leaflet motions occur: two leaflets move asymmetrically, and valve closing is delayed in time or incomplete, which increases the regurgitation volume. The peak energy loss coefficients due to panni are obtained from simulation data and compared with those predicted by a one-dimensional model. The comparison indicates that the one-dimensional model is applicable for the BMHV with and without pannus.

Indexed as

Models, CardiovascularAortic ValveBlood PressureComputer SimulationFibrosisHeart Valve ProsthesisHemodynamicsHemorheologyHumansMotionProsthesis Design

Identifiers

PMID32530931
PMCPMC7292405
OpenAlexW2599122660

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.