Evidence map›Paper›PMID 32530868›Full record

ArticleInvestigative radiology2020

Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study.

Liqiang Ren, Kishore Rajendran, Joel G Fletcher, Cynthia H McCollough, Lifeng Yu

Open access · greenAbstract read
In one paragraph

Article in Investigative radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 35 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Oral CT Contrast Agents: What's New and Why, From theAJR. American journal of roentgenology · 2024
    Review
  6. Article
  7. Review
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Liqiang RenFrom the Department of Radiology, Mayo Clinic, Rochester, MN.
Kishore Rajendran
Joel G Fletcher
Cynthia H McCollough
Lifeng Yu
Mayo Clinic in Arizona · US

Funding

Photon-Counting Spectral CT to Reduce Dose and Detect Early Vascular DiseaseR01EB016966 · NIBIB · MAYO CLINIC ROCHESTER · PI MCCOLLOUGH, CYNTHIA H · 2013 to 2017
$5.1M
EXTRAMURAL RES FACIL IMPROVEMENT PROG: POLYCYSTIC KIDNEY DISEASE, RENAL STUDIES,C06RR018898 · NCRR · MAYO CLINIC · PI BURNETT, JOHN C · 2004 to 2004
$2.3M
Multi-energy CT with Energy-integrating DetectorR21EB024071 · NIBIB · MAYO CLINIC ROCHESTER · PI YU, LIFENG · 2017 to 2018
$437k
NCRR NIH HHS C06 RR018898NIBIB NIH HHS R01 EB016966NIBIB NIH HHS R21 EB024071
6 · The paper itself

Abstract

objectivesDual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. MATERIALS AND

methodsA phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV.

resultsUsing a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL.

conclusionsOur study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.

Indexed as

BismuthIodinePhotonsAnimalsContrast MediaFeasibility StudiesHumansIntestine, SmallPhantoms, ImagingSwineTomography, X-Ray ComputedBismuthContrast MediaIodine

Identifiers

PMID32530868
PMCPMC7808340
OpenAlexW3034892973

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.