Evidence map›Paper›PMID 32523484›Full record

ReviewHSS journal : the musculoskeletal journal of Hospital for Special Surgery2020

Interbody Fusions in the Lumbar Spine: A Review.

Ravi Verma, Sohrab Virk, Sheeraz Qureshi

Open access · greenAbstract readReview
In one paragraph

Review in HSS journal : the musculoskeletal journal of Hospital for Special Surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 1 pooled it
5.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 1 synthesis or guideline pooled it, 82 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. The association between postoperative physical therapy and opioid prescription after posterior lumbar interbody fusion: a retrospective cohort study of United States academic health centers.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ravi VermaDepartment of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th St., New York, NY 10021 USA.
Sohrab VirkDepartment of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th St., New York, NY 10021 USA.ORCID 0000-0001-9617-1987
Sheeraz QureshiDepartment of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th St., New York, NY 10021 USA.
Hospital for Special Surgery · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLumbar interbody fusion is among the most common types of spinal surgery performed. Over time, the term has evolved to encompass a number of different approaches to the intervertebral space, as well as differing implant materials. Questions remain over which approaches and materials are best for achieving fusion and restoring disc height. QUESTIONS/PURPOSES: We reviewed the literature on the advantages and disadvantages of various methods and devices used to achieve and augment fusion between the disc spaces in the lumbar spine.

methodsUsing search terms specific to lumbar interbody fusion, we searched PubMed and Google Scholar and identified 4993 articles. We excluded those that did not report clinical outcomes, involved cervical interbody devices, were animal studies, or were not in English. After exclusions, 68 articles were included for review.

resultsPosterior approaches have advantages, such as providing 360° support through a single incision, but can result in retraction injury and do not always restore lordosis or correct deformity. Anterior approaches allow for the largest implants and good correction of deformities but can result in vascular, urinary, psoas muscle, or lumbar plexus injury and may require a second posterior procedure to supplement fixation. Titanium cages produce improved osteointegration and fusion rates but also increase subsidence caused by the stiffness of titanium relative to bone. Polyetheretherketone (PEEK) has an elasticity closer to that of bone and shows less subsidence than titanium cages, but as an inert compound PEEK results in lower fusion rates and greater osteolysis. Combination PEEK-titanium coating has not yet achieved better results. Expandable cages were developed to increase disc height and restore lumbar lordosis, but the data on their effectiveness have been inconclusive. Three-dimensionally (3D)-printed cages have shown promise in biomechanical and animal studies at increasing fusion rates and reducing subsidence, but additive manufacturing options are still in their infancy and require more investigation.

conclusionsAll of the approaches to spinal fusion have plusses and minuses that must be considered when determining which to use, and newer-technology implants, such as PEEK with titanium coating, expandable, and 3D-printed cages, have tried to improve upon the limitations of existing grafts but require further study.

Indexed as

ALIFLLIFlumbar interbody fusionOLIF

Identifiers

PMID32523484
PMCPMC7253570
OpenAlexW3000400317

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.