Evidence map›Paper›PMID 32520529›Full record

ArticleAnalytical chemistry2020

Thermal Desorption-Vocus Enables Online Nondestructive Quantification of 2,4,6-Trichloroanisole in Cork Stoppers below the Perception Threshold.

Luca Cappellin, Felipe D Lopez-Hilfiker, Veronika Pospisilova, Luigi Ciotti, Paolo Pastore, Marc Gonin, Manuel A Hutterli

Open access · hybridAbstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Uncorking Haloanisoles in Wine.Molecules (Basel, Switzerland) · 2023
    Review
  6. 2,4,6-Trichloroanisole Off-Flavor Screening in GreenJournal of agricultural and food chemistry · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Luca CappellinDipartimento di Scienze Chimiche, Università degli Studi di Padova, via Marzolo 1, 35131 Padova, Italy.ORCID 0000-0001-6740-3638
Felipe D Lopez-HilfikerTofwerk AG, Schorenstrasse 39, CH-3645 Thun, Switzerland.
Veronika PospisilovaTofwerk AG, Schorenstrasse 39, CH-3645 Thun, Switzerland.
Luigi CiottiTofwerk AG, Schorenstrasse 39, CH-3645 Thun, Switzerland.
Paolo PastoreDipartimento di Scienze Chimiche, Università degli Studi di Padova, via Marzolo 1, 35131 Padova, Italy.
Marc GoninTofwerk AG, Schorenstrasse 39, CH-3645 Thun, Switzerland.
Manuel A HutterliTofwerk AG, Schorenstrasse 39, CH-3645 Thun, Switzerland.
Tofwerk (Switzerland) · CHFondazione Edmund Mach · ITUniversity of Padua · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

2,4,6-Trichloroanisole (TCA) contamination of wine determines huge economic losses for the wine industry estimated to amount to several billion dollars yearly. Over 50 years of studies have determined that this problem is often caused by TCA contamination of the cork stopper, which releases TCA into the wine. The human threshold for TCA is extremely low. A wine contaminated by 1-2 ng/L TCA can be perceived as tainted. Contaminations with <0.5 ng/L TCA are commonly considered negligible and are not perceivable. The possibility of prescreening cork stoppers for TCA contamination would be an enormous advantage. Therefore, the demand for a fast, nondestructive method capable of quantifying the TCA contamination in cork stoppers is impelling. Vastly used analytical methods have so far struggled to provide a fast and reliable solution, whereas sensory analysis by trained panelists is expensive and time-consuming. Here we propose a novel approach based on chemical ionization-time-of-flight (CI-TOF) mass spectrometry employing the "Vocus" ion source and ion-molecule reactor. The technique proved capable of nondestructively quantifying TCA contamination in a single cork stopper in 3 s, with a limit of quantification below the perception threshold. A real test on the industrial scale, quantifying TCA contamination in more than 10000 cork stoppers in a few hours is presented, representing the largest data set of TCA analysis on cork stoppers within the literature and proving the possibility to apply the technique in an industrial environment. The correlation with standard methods for releasable TCA quantification is also discussed.

Indexed as

AnisolesFood ContaminationHumansMass SpectrometryTasteWine2,4,6-trichloroanisoleAnisoles

Identifiers

PMID32520529
PMCPMC8008374
OpenAlexW3033704499

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.