Evidence map›Paper›PMID 32518250›Full record

ArticleNature communications2020

Pushing the boundaries of optoacoustic microscopy by total impulse response characterization.

Markus Seeger, Dominik Soliman, Juan Aguirre, Gael Diot, Jakob Wierzbowski, Vasilis Ntziachristos

Abstract read
In one paragraph

Article in Nature communications, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Label-Free 3D Photoacoustic Imaging of Tumor Organoids for Volumetric Drug Screening.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Multiscale confocal photoacoustic dermoscopy to evaluate skin health.Quantitative imaging in medicine and surgery · 2022
    Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Markus SeegerChair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany.ORCID http://orcid.org/0000-0002-4588-0393
Dominik SolimanChair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany.
Juan AguirreChair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany.
Gael DiotChair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany.
Jakob WierzbowskiWalter Schottky Institute, Physics Department, Technical University of Munich, Am Coulombwall 4, 85748, Garching, Germany.
Vasilis NtziachristosChair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany. v.ntziachristos@tum.de.ORCID http://orcid.org/0000-0002-9988-0233

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical microscopy improves in resolution and signal-to-noise ratio by correcting for the system's point spread function; a measure of how a point source is resolved, typically determined by imaging nanospheres. Optical-resolution optoacoustic (photoacoustic) microscopy could be similarly corrected, especially to account for the spatially-dependent signal distortions induced by the acoustic detection and the time-resolved and bi-polar nature of optoacoustic signals. Correction algorithms must therefore include the spatial dependence of signals' origins and profiles in time, i.e. the four-dimensional total impulse response (TIR). However, such corrections have been so far impeded by a lack of efficient TIR-characterization methods. We introduce high-quality TIR determination based on spatially-distributed optoacoustic point sources (SOAPs), produced by scanning an optical focus on an axially-translatable 250 nm gold layer. Using a spatially-dependent TIR-correction improves the signal-to-noise ratio by >10 dB and the axial resolution by ~30%. This accomplishment displays a new performance paradigm for optoacoustic microscopy.

Identifiers

PMID32518250
PMCPMC7283257

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.