Evidence map›Paper›PMID 32517709›Full record

ArticleBMC gastroenterology2020

Optimization of impedance-measured reflux events in GORD utilizing acid exposure time.

Anthony J Horton, Steven B Clayton

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in BMC gastroenterology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Laryngopharyngeal Reflux Prevalence and Predictors Among Doctors.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2025
    Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Anthony J HortonDepartment of Medicine, Duke University Health System, Durham, NC, USA.
Steven B ClaytonGastroenterology and Liver Center, Greenville Health System, Greenville, SC, USA. sbclayto@wakehealth.edu.ORCID http://orcid.org/0000-0002-0492-6201
Atrium Health Wake Forest Baptist · USDuke University Health System · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCombining impedance with pH monitoring improves the detection and characterization of gastro-oesophageal reflux (GOR), yet the two modalities frequently differ in GOR quantification. Ambulatory 24-h pH-impedance monitoring often reveals more significant oesophageal acid exposure than impedance-measured reflux activity in patients with symptomatic gastro-oesophageal reflux disease (GORD). The purpose of this study is to elucidate the discrepancies between these modalities by assessing the predictive accuracy of impedance compared to acid exposure standards.

methodsA single-institution, retrospective review of sequential 24-h pH-impedance results of 72 patients with symptomatic GOR off anti-secretory therapy was conducted. Reflux events measured by impedance were stratified by patient position and compared to oesophageal acid exposure time (AET). Oesophageal AET limits for GORD detection were utilized as gold standards to generate serial receiver operator characteristics (ROC) curves to assess the sensitivity and specificity of current impedance GORD detection limits and identify optimized impedance standards based on area under the curve (AUC) analysis.

resultsMean total AET time was 10.5% (± 9.9%), and 63.8% of patients had elevated AET. By impedance, median GOR frequency was 43 (IQR 21-68), and 22.2% exceeded conventional GOR frequency limits of normal. ROC curve analysis revealed the current impedance standard of > 73 GOR events has a sensitivity of 32.6% and specificity of 96.5% (AUC 0.74) for GORD detection. By AUC analysis, an impedance threshold of > 41 GOR events is optimal for GORD detection (sensitivity 69.6%, specificity 80.7%, AUC 0.83).

conclusionConventional impedance standards for abnormal GOR frequency are weakly sensitive for the detection of GORD, providing a possible explanation to discrepancies in AET and impedance interpretation. Lowering impedance-measured GOR frequency limits to > 41 optimizes sensitivity and specificity while increasing congruence between pH and impedance metrics.

Indexed as

Electric ImpedanceTime FactorsAdultAgedAged, 80 and overEsophageal pH MonitoringFemaleGastroesophageal RefluxHumansMaleMiddle AgedReproducibility of ResultsRetrospective StudiesROC CurveSensitivity and SpecificityAmbulatory reflux monitoringGastro-oesophageal reflux diseaseMultichannel intraluminal pHpH-impedance

Identifiers

PMID32517709
PMCPMC7281954
OpenAlexW3033010174

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked