Evidence map›Paper›PMID 32517263›Full record

ArticleMembranes2020

Free Standing, Large-Area Silicon Nitride Membranes for High Toxin Clearance in Blood Surrogate for Small-Format Hemodialysis.

Joshua J Miller, Jared A Carter, Kayli Hill, Jon-Paul S DesOrmeaux, Robert N Carter, Thomas R Gaborski, James A Roussie, James L McGrath, Dean G Johnson

Open access · goldAbstract read
In one paragraph

Article in Membranes, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Joshua J MillerSiMPore, Inc. 150 Lucius Gordon Drive, Suite 110, West Henrietta, NY 14586, USA.
Jared A CarterSiMPore, Inc. 150 Lucius Gordon Drive, Suite 110, West Henrietta, NY 14586, USA.
Kayli HillBiomedical Engineering Department, University of Rochester, Rochester, NY 14627, USA.
Jon-Paul S DesOrmeauxSiMPore, Inc. 150 Lucius Gordon Drive, Suite 110, West Henrietta, NY 14586, USA.
Robert N CarterMechanical Engineering Department, Rochester Institute of Technology, Rochester, NY 14623, USA.
Thomas R GaborskiBiomedical Engineering Department, Rochester Institute of Technology, Rochester, NY 14623, USA.ORCID 0000-0002-3676-3208
James A RoussieSiMPore, Inc. 150 Lucius Gordon Drive, Suite 110, West Henrietta, NY 14586, USA.
James L McGrathBiomedical Engineering Department, University of Rochester, Rochester, NY 14627, USA.
Dean G JohnsonBiomedical Engineering Department, University of Rochester, Rochester, NY 14627, USA.ORCID 0000-0002-5182-9826
SiMPore (United States) · USUniversity of Rochester · USRochester Institute of Technology · US

Funding

VISUAL INDICES OF NEUROTOXICITYP30ES001247 · NIEHS · UNIVERSITY OF ROCHESTER · PI Martha Susiarjo · 1985 to 2026
$42.8M
Novel Sheet-Membrane Dialyzer for Wearable HemodialysisR01DK126901 · NIDDK · UNIVERSITY OF ROCHESTER · PI JOHNSON, DEAN G · 2020 to 2024
$1.5M
Novel Ultra-Permeable Membrane-based Dialyzer for Home HemodialysisK25DK106503 · NIDDK · UNIVERSITY OF ROCHESTER · PI JOHNSON, DEAN G · 2016 to 2020
$675k
Fresenius Medical Care, Inc FMC-Fellow2017National Science Foundation IIP1660177NHLBI NIH HHS EB021026NIDDK NIH HHS DK106503-01A1NIDDK NIH HHS K25 DK106503NIDDK NIH HHS R01 DK126901NIEHS NIH HHS P30 ES001247
6 · The paper itself

Abstract

Developing highly-efficient membranes for toxin clearance in small-format hemodialysis presents a fabrication challenge. The miniaturization of fluidics and controls has been the focus of current work on hemodialysis (HD) devices. This approach has not addressed the membrane efficiency needed for toxin clearance in small-format hemodialysis devices. Dr. Willem Kolff built the first dialyzer in 1943 and many changes have been made to HD technology since then. However, conventional HD still uses large instruments with bulky dialysis cartridges made of ~2 m

Indexed as

hemodialysismodelnanomembranes

Identifiers

PMID32517263
PMCPMC7344517
OpenAlexW3033453880

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.