Evidence map›Paper›PMID 32512812›Full record

ArticleDiagnostics (Basel, Switzerland)2020

Evaluation of ViroTrack Sero Zika IgG/IgM, a New Rapid and Quantitative Zika Serological Diagnostic Assay.

Tony Liao, Xiaole Wang, Marco Donolato, Eva Harris, Magelda Montoya Cruz, Angel Balmaseda, Robert Y L Wang

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Tony LiaoChang Gung Biotechnology Industry Master and PhD Program, Chang Gung University, Taoyuan 33302, Taiwan.
Xiaole WangBluSense Diagnostics, Fruebjergvej 3, DK-2100 Copenhagen, Denmark.
Marco DonolatoBluSense Diagnostics, Fruebjergvej 3, DK-2100 Copenhagen, Denmark.
Eva HarrisDivision of Infectious Diseases and Vaccinology, School of Public Health, University of California, Berkeley, CA 94720, USA.
Magelda Montoya CruzDivision of Infectious Diseases and Vaccinology, School of Public Health, University of California, Berkeley, CA 94720, USA.
Angel BalmasedaNational Virology Laboratory, National Center for Diagnosis and Reference, Ministry of Health, 107 Managua, Nicaragua.
Robert Y L WangChang Gung Biotechnology Industry Master and PhD Program, Chang Gung University, Taoyuan 33302, Taiwan.ORCID 0000-0002-1322-3890
Chang Gung University · TWUniversity of California, Berkeley · US

Funding

T Cell Responses Following DENV Natural Infections and Live-Attenuated Dengue Virus VaccinationP01AI106695 · NIAID · UNIVERSITY OF CALIFORNIA BERKELEY · PI Aravinda M. DeSilva · 2015 to 2026
$34.1M
Molecular Basis of Flavivirus Cross-Neutralization by Human AntibodiesR01AI107731 · NIAID · UNIV OF NORTH CAROLINA CHAPEL HILL · PI DESILVA, ARAVINDA M. · 2013 to 2022
$5.3M
NIAID NIH HHS P01 AI106695NIAID NIH HHS R01 AI107731
6 · The paper itself

Abstract

Dengue virus (DENV) and Zika virus (ZIKV) belong to the flavivirus genus and are antigenically closely related. They also share the same mosquito vector and can cause similar symptoms upon infection. However, DENV and ZIKV infections lead to different clinical sequelae and treatments; therefore, clinicians need rapid and accurate diagnostics capable of distinguishing between the two diseases.

methodsWe employed the immuno-magnetic assay technology on a microfluidic cartridge (ViroTrack Sero Zika IgG/IgM) for diagnosis of ZIKV infection based on the aggregation of magnetic nanoparticles. We carried out three serological studies including samples from the Dominican Republic, USA, and Nicaragua, aimed at detecting ZIKV-specific IgG and IgM using the ViroTrack Sero Zika IgG/IgM test.

resultsThe seroconversion results were comparable with ZIKV IgG and IgM reactivity measured by the commercial ZIKV ELISA kit. The sensitivity and specificity for both ZIKV IgG and IgM tested by the ViroTrack Sero Zika IgG/IgM was approximately 98% and 93%, respectively.

conclusionSerological detection of ZIKV infection by the new ViroTrack Sero Zika IgG/IgM test shows promising performance and limited cross-reactivity with DENV.

Indexed as

dengue virusdiagnosisimmuno-magnetic assayViroTrack Sero Zika IgG/IgMZika virus

Identifiers

PMID32512812
PMCPMC7345115
OpenAlexW3033978677

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.