ArticleDocumenta ophthalmologica. Advances in ophthalmology2020
Normal to supernormal 30-Hz flicker ERGs predict visual function and prognosis in central retinal artery occlusion.
Article in Documenta ophthalmologica. Advances in ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo determine whether normal to supernormal 30-Hz flicker ERGs are associated with visual function and prognosis in patients with central retinal artery occlusion (CRAO).
methodsA total of 133 patients diagnosed with unilateral acute non-arteritic CRAO by examination with electroretinography (ERG) were examined. Thirty-hertz flicker ERG amplitudes were analyzed according to the severity of CRAO, and their correlation with visual function and prognosis was assessed. All patients were categorized into one of three groups according to the flicker ERG amplitude ratios between affected and fellow eyes: ≥ 110%, supernormal; 90-110%, normal; and < 90%, subnormal.
resultsThirty-hertz flicker ERG parameters differed significantly according to the severity of retinal ischemia, i.e., between incomplete versus complete CRAO: mean amplitude (55.89 ± 24.38 > 45.41 ± 23.47 μV, P = 0.029), amplitude ratio (76.1 ± 23.1% > 58.7 ± 25.7%, P < 0.001), and proportion of normal to supernormal flicker ERGs (30.5% > 12.4%, P < .001). One-month and final follow-up visual function and prognosis were better in the normal to supernormal flicker ERGs: 1 month BCVA (1.55 ± 0.65 > 2.05 ± 0.61 logMAR, P < .001), final BCVA (1.32 ± 0.79 > 1.97 ± 0.68 logMAR, P < .001), 1-month VA improvement (- 0.50 ± 0.47 > - 0.10 ± 0.29 logMAR, P < .001), and final VA improvement (- 0.74 ± 0.61 > - 0.18 ± 0.37 logMAR, P < .001).
conclusionsNormal to supernormal 30-Hz flicker ERG changes in eyes with CRAO are associated with the milder severity of retinal ischemia and showed better visual function and outcome than the subnormal ERG group.
Indexed as
Identifiers
What OpenQuestion holds