Evidence map›Paper›PMID 32504134›Full record

ArticleEuropean journal of pediatrics2021

Oxygen saturation and perfusion index screening in neonates at high altitudes: can PDA be predicted?

Kadir Şerafettin Tekgündüz, Merve Bilen, Mustafa Kara, Fuat Laloğlu, Naci Ceviz

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in European journal of pediatrics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05468515 (Reference Interval for Pulse Oxygen Saturation in Neonates at High Altitudes During First 2 Hours and Umbilical Artery Blood Gas), which is not on this map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05468515 completednot on this mapstarted 2022, after this paper: background citation

Reference Interval for Pulse Oxygen Saturation in Neonates at High Altitudes During First 2 Hours and Umbilical Artery Blood Gas: a Multicenter Prospective Study

TypeobservationalSponsorChildren's Hospital of Fudan UniversityRan2022 to 2023Enrolled956ConditionsNeonatal Disease, Altitude HypoxiaArmspulse oxygen saturation
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kadir Şerafettin TekgündüzDepartment of Pediatrics, Division of Neonatology, Ataturk University Medical Faculty, Erzurum, Turkey. k.tekgunduz@yahoo.com.tr.ORCID http://orcid.org/0000-0001-6375-5644
Merve BilenDepartment of Pediatrics, Ataturk University Medical Faculty, Erzurum, Turkey.
Mustafa KaraDepartment of Pediatrics, Division of Neonatology, Ataturk University Medical Faculty, Erzurum, Turkey.
Fuat LaloğluDepartment of Pediatrics, Division of Pediatric Cardiology, Ataturk University Medical Faculty, Erzurum, Turkey.
Naci CevizDepartment of Pediatrics, Division of Pediatric Cardiology, Ataturk University Medical Faculty, Erzurum, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Screening critical congenital heart disease in neonates with 24-48 h of age could be made by oxygen saturation determination. Perfusion index may be used as an adjunct to pulse oximetry screening to detect non-cyanotic critical congenital heart disease cases such as a left heart outflow obstruction. We evaluate the results of combined screening for oxygen saturation and peripheral perfusion index at high altitudes. The study included 501 neonates older than gestational week 35. The mean oxygen saturation was lower than at sea level, and the screening test was positive in a total of 21 (4.2%) babies. Critical congenital heart diseases were not detected in any patient. A total of 10 (2%) babies were detected with PDA, nine (1.8%) of whom recorded a positive screening test. The prevalence of PDA was significantly higher in the positive screening test group when compared with those who underwent echocardiography due to clinical findings.Conclusion: The median peripheral perfusion index at high altitude was not lower than at sea level, while the mean oxygen saturation, in contrast, was lower than at sea level. The low partial oxygen pressure found at high altitudes leads to a variation in postnatal adaptation and an increased prevalence of PDA. Accordingly, oxygen saturation screening may serve to identify babies with PDA at high altitudes. What is Known: • Oxygen saturation is known to be low at high altitudes, and thus the rates of false positivity are high when screening for critical congenital heart disease. • High altitudes are also associated with an increased prevalence of simple congenital heart disease. What is New: • The peripheral perfusion index at high altitude is not lower than at sea level. • The prevalence of PDA is significantly higher in those with false positive screening results.

Indexed as

AltitudeHeart Defects, CongenitalHumansInfant, NewbornOximetryOxygenPerfusion IndexOxygenCongenitalHigh altitudeNeonateOxygen saturationPatent ductus arteriosus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.