ArticleClinical oral investigations2021
Implant removal using thermal necrosis-an in vitro pilot study.
Article in Clinical oral investigations, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Systemic and local effects of vancomycin-combined thermal exposure on Staphylococcus aureus infected rat femurs: a comparative study of hyperthermia and thermal ablation.Naunyn-Schmiedeberg's archives of pharmacology · 2026Article
- SEM Evaluation of Surface Wear on Drills from Selected Implant Systems-In Vitro Study.Materials (Basel, Switzerland) · 2026Article
- Thermal analysis of a dry cooling method in a dental implant drilling procedure: an in vitro randomized study.BMC oral health · 2025Article
- Thermal implant removal in a pig jaw: a proof of concept study.Clinical oral investigations · 2024Article
- Evaluation of in vitro biocompatibility of human pulp stem cells with allogeneic, alloplastic, and xenogeneic grafts under the influence of extracellular vesicles.Scientific reports · 2023Article
- Results of thermal osteonecrosis for implant removal on electron microscopy, implant stability, and radiographic parameters - a rat study.Head & face medicine · 2023Article
- Thermal necrosis-aided dental implant removal: A rabbit model pilot study.Medicina oral, patologia oral y cirugia bucal · 2023Article
- Effect of systemic antiresorptive medication on the histopathological parameters of implant osseointegration in an in vivo rodent study.BMC oral health · 2023Article
- In vitro comparison of the osteogenic capability of human pulp stem cells on alloplastic, allogeneic, and xenogeneic bone scaffolds.BMC oral health · 2023Article
- Effect of thermal osteonecrosis around implants in the rat tibia: numerical and histomorphometric results in context of implant removal.Scientific reports · 2022Article
- Non-Destructive Removal of Dental Implant by Using the Cryogenic Method.Medicina (Kaunas, Lithuania) · 2022Article
- Evaluation of Implant Stability and Trephination Depth for Implant Removal-An In Vitro Study.Materials (Basel, Switzerland) · 2022Article
- Human amniotic membrane application in oral surgery-AnFrontiers in bioengineering and biotechnology · 2022Article
- In vivo and in vitro analysis in a rat model using zoledronate and alendronate medication: microbiological and scanning electron microscopy findings on peri-implant rat tissue.BMC oral health · 2021Article
- Reversal of Osseointegration as a Novel Perspective for the Removal of Failed Dental Implants: A Review of Five Patented Methods.Materials (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
objectivesThe purpose of this pilot porcine cadaver study was to evaluate the feasible temperature thresholds, which affect osteocyte viability and bone matrix in a preclinical setup, assessing the potential of thermal necrosis for implant removal for further in vivo investigations. MATERIALS AND
methodsAfter implant bed preparation in the upper and lower jaw, temperature effects on the bone were determined, using two tempering pistons with integrated thermocouples. To evaluate threshold temperature and time intervals leading to bone necrosis, one piston generated warm temperatures at 49 to 56 °C for 10 s and the other generated cold temperatures at 5 to 1 °C for 30 s. Effects were assessed by a semi-quantitative, histomorphometrical scoring system, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and transmission electron microscopy (TEM).
resultsThe bone matrix was significantly degenerated starting at 51 °C for 10 s and 5 °C for 30 s. The osteocyte condition indicated significant bone damage beginning at cold temperatures of 2 °C. Temperature inputs starting at 53 °C led to decalcification and swollen mitochondria, which lost the structure of their inner cristae.
conclusionsThis study identified temperatures and durations, in both heat and cold, so that the number of samples may be kept low in further studies regarding temperature-induced bone necrosis. Levels of 51 °C for 10 s and 5 °C for 30 s have presented significant matrix degeneration. CLINICAL RELEVANCE: Temperature thresholds, potentially leading to thermo-explantation of dental implants and other osseointegrated devices, were identified.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.