Evidence map›Paper›PMID 32498843›Full record

ArticleTalanta2020

Design and fabrication of a highly sensitive and naked-eye distinguishable colorimetric biosensor for chloramphenicol detection by using ELISA on nanofibrous membranes.

Cunyi Zhao, Yang Si, Bofeng Pan, Ameer Y Taha, Tingrui Pan, Gang Sun

Open access · greenAbstract read
In one paragraph

Article in Talanta, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 79 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Sample-to-Answer Robotic ELISA.Analytical chemistry · 2021
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Cunyi ZhaoBiological and Agricultural Engineering, University of California, Davis, CA, 95616, USA.
Yang SiBiological and Agricultural Engineering, University of California, Davis, CA, 95616, USA.
Bofeng PanBiological and Agricultural Engineering, University of California, Davis, CA, 95616, USA.
Ameer Y TahaFood Science and Technology, University of California, Davis, CA, 95616, USA.
Tingrui PanBiomedical Engineering, University of California, Davis, CA, 95616, USA.
Gang SunBiological and Agricultural Engineering, University of California, Davis, CA, 95616, USA. Electronic address: gysun@ucdavis.edu.
University of California, Davis · US

Funding

Workshop on Environmental Technology Transfer and EntrepreneurshipP42ES004699 · NIEHS · UNIVERSITY OF CALIFORNIA DAVIS · PI HAMMOCK, BRUCE D · 1987 to 2021
$50.1M
NIEHS NIH HHS P42 ES004699
6 · The paper itself

Abstract

Enzyme-linked immunoassay (ELISA) is highly specific and selective towards target molecules and is convenient for on-site detection. However, in many cases, lack of high sensitivity makes it hard to reveal a significant colorimetric signal for detecting a trace amount of target molecules. Thus, analytical instruments are required for detection, which limits the application of ELISA for on-site detection. In the present study, a highly sensitive and naked-eyed detectable colorimetric biosensor for chloramphenicol (CAP) was prepared by incorporating ELISA onto surfaces of microporous and nanofibrous membranes. The high specific surface areas of the nanofibers significantly increased the number of antibodies covalently linked onto the fiber surfaces and binding capacity of the sensor with antigens present in a sample. With such an integration, the sensitivity of the ELISA sensor was dramatically increased, and a trace number of targets could reveal a naked-eye detectable color. The immunoassay sensor exhibited a significant naked-eye distinguishable color to chloramphenicol (CAP) at 0.3 ng/mL. The successful design and fabrication of the nanofibrous membrane immunoassay sensor provide new paths towards the development of on-site inspection sensors without the assistance from any instrument.

Indexed as

Biosensing TechniquesColorimetryEnzyme-Linked Immunosorbent AssayChloramphenicolNanofibersParticle SizeSurface PropertiesChloramphenicolChloramphenicolColorimetric sensorEnzyme-linked immunoassayEnzyme-linked immunosorbent assayNaked-eye distinctionNanofibrous membrane

Identifiers

PMID32498843
PMCPMC7304426
OpenAlexW3016371671

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked