Evidence map›Paper›PMID 32497304›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2021

Changes in knee adduction moment wearing a variable-stiffness shoe correlate with changes in pain and mechanically stimulated cartilage oligomeric matrix levels.

Jennifer C Erhart-Hledik, Gordhan B Mahtani, Jessica L Asay, Eleonora Migliore, Michelle M Nguyen, Thomas P Andriacchi, Constance R Chu

Open access · bronzeAbstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jennifer C Erhart-HledikDepartment of Orthopaedic Surgery, Stanford University, Stanford, California.ORCID 0000-0002-3616-6585
Gordhan B MahtaniDepartment of Orthopaedic Surgery, Stanford University, Stanford, California.ORCID 0000-0001-7549-6504
Jessica L AsayVA Palo Alto Health Care System, Palo Alto, California.ORCID 0000-0002-6853-5461
Eleonora MiglioreDepartment of Orthopaedic Surgery, Stanford University, Stanford, California.
Michelle M NguyenVA Palo Alto Health Care System, Palo Alto, California.
Thomas P AndriacchiVA Palo Alto Health Care System, Palo Alto, California.
Constance R ChuDepartment of Orthopaedic Surgery, Stanford University, Stanford, California.
VA Palo Alto Health Care System · US

Funding

RRD VA I21 RX002045
6 · The paper itself

Abstract

This study aimed to determine if changes in knee adduction moment (KAM) after 6 months of variable-stiffness shoe wear are associated with changes in symptoms or serum levels of cartilage oligomeric matrix protein (COMP) following a mechanical stimulus in subjects with medial knee osteoarthritis (OA). Twenty-five subjects were enrolled in the study and assigned a variable-stiffness shoe, and 19 subjects completed the 6-month follow-up. At baseline and follow-up subjects underwent gait analysis in control and variable-stiffness shoes, completed Western Ontario and McMaster Universities (WOMAC) questionnaires, and serum COMP concentrations were measured immediately before, 3.5 and 5.5 hours after a 30-minute walking activity. Relationships between changes in KAM (first peak and impulse) and changes in (a) COMP levels in response to the 30-minute walking activity and (b) WOMAC scores from baseline to 6-month follow-up were assessed by Pearson correlation coefficients. Changes in first peak KAM were associated with changes in COMP levels 5.5 hours postactivity from baseline to follow-up (R = .564, P = .045). Subjects with greater reductions in KAM had larger decreases in COMP (expressed as a percent of preactivity levels) at follow-up. Subjects with greater reductions in KAM impulse had significantly greater improvements in WOMAC Pain (R = -.56, P = .015) and Function (R = -.52, P = .028) scores at follow-up. The study results demonstrated the magnitude of reduction in the KAM wearing a variable-stiffness shoe is associated with decreases in mechanically stimulated COMP levels and pain/function. This work suggests that interactions between COMP and joint loading during walking should be further investigated in future studies of treatment outcomes in OA.

Indexed as

AgedCartilage Oligomeric Matrix ProteinFemaleFoot OrthosesHumansKnee JointMaleMiddle AgedOsteoarthritis, KneePainProspective StudiesSeverity of Illness IndexShoesWeight-BearingCartilage Oligomeric Matrix ProteinTSP5 protein, humancartilage oligomeric matrix proteinknee adduction momentosteoarthritispainvariable-stiffness shoe

Identifiers

PMID32497304
PMCPMC12433613
OpenAlexW3033080475

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.