ArticleQuantitative imaging in medicine and surgery2020

Fast Fourier transform combined with phase leading compensator for respiratory motion compensation system.

Chia-Chun Kuo, Ho-Chiao Chuang, Ai-Ho Liao, Hsiao-Wei Yu, Syue-Ru Cai, Der-Chi Tien, Shiu-Chen Jeng, Jeng-Fong Chiou

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Chia-Chun KuoDepartment of Radiation Oncology, Taipei Medical University Hospital, Taipei, Taiwan.
Ho-Chiao ChuangDepartment of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan.
Ai-Ho LiaoGraduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
Hsiao-Wei YuTaipei Cancer Center, Taipei Medical University, Taipei, Taiwan.
Syue-Ru CaiDepartment of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan.
Der-Chi TienDepartment of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan.
Shiu-Chen JengDepartment of Radiation Oncology, Taipei Medical University Hospital, Taipei, Taiwan.
Jeng-Fong ChiouDepartment of Radiation Oncology, Taipei Medical University Hospital, Taipei, Taiwan.
National Taipei University of Technology · TWTaipei Medical University · TWNational Taiwan University of Science and Technology · TWTaipei Medical University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe reduction of the delaying effect in the respiratory motion compensation system (RMCS) is still impossible to completely correct the respiratory waveform of the human body due to each patient has a unique respiratory rate. In order to further improve the effectiveness of radiation therapy, this study evaluates our previously developed RMCS and uses the fast Fourier transform (FFT) algorithm combined with the phase lead compensator (PLC) to further improve the compensation rate (CR) of different respiratory frequencies and patterns of patients.

methodsIn this study, an algorithm of FFT automatic frequency detection was developed by using LabVIEW software, uisng FFT combined with PLC and RMCS to compensate the system delay time. Respiratory motion compensation experiments were performed using pre-recorded respiratory signals of 25 patients. During the experiment, the respiratory motion simulation system (RMSS) was placed on the RMCS, and the pre-recorded patient breathing signals were sent to the RMCS by using our previously developed ultrasound image tracking algorithm (UITA). The tracking error of the RMCS is obtained by comparing the encoder signals of the RMSS and RMCS. The compensation effect is verified by root mean squared error (RMSE) and system CR.

resultsThe experimental results show that the patient's respiratory patterns compensated by the RMCS after using the proposed FFT combined with PLC control method, the RMSE is between 1.50-5.71 and 3.15-8.31 mm in the right-left (RL) and superior-inferior (SI) directions, respectively. CR is between 72.86-93.25% and 62.3-83.81% in RL and SI, respectively.

conclusionsThis study used FFT combined with PLC control method to apply to RMCS, and used UITA for respiratory motion compensation. Under the automatic frequency detection, the best dominant frequency of the human respiratory waveform can be determinated. In radiotherapy, it can be used to compensate the tumor movement caused by respiratory motion and reduce the radiation damage and side effects of normal tissues nearby the tumor.

Indexed as

Fast Fourier transform (FFT)respiratory motion compensationultrasound image tracking