Evidence map›Paper›PMID 32486824›Full record

ArticleThe Journal of the Acoustical Society of America2020

The effect of size range on ultrasound-induced translations in microbubble populations.

Outi Supponen, Awaneesh Upadhyay, Jordan Lum, Francesco Guidi, Todd Murray, Hendrik J Vos, Piero Tortoli, Mark Borden

Abstract read
In one paragraph

Article in The Journal of the Acoustical Society of America, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Frequency-Selective Microbubble TargetingACS applied bio materials · 2025
    Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Outi SupponenDepartment of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland.ORCID s0000000167380675
Awaneesh UpadhyayDepartment of Mechanical Engineering, University of Colorado Boulder, 1111 Engineering Drive, Boulder, Colorado 80309, USA.
Jordan LumDepartment of Mechanical Engineering, University of Colorado Boulder, 1111 Engineering Drive, Boulder, Colorado 80309, USA.
Francesco GuidiDepartment of Information Engineering, University of Florence, Via di S. Marta 3, 50139 Florence, Italy.
Todd MurrayDepartment of Mechanical Engineering, University of Colorado Boulder, 1111 Engineering Drive, Boulder, Colorado 80309, USA.
Hendrik J VosDepartment of Biomedical Engineering, Erasmus MC, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands.
Piero TortoliDepartment of Information Engineering, University of Florence, Via di S. Marta 3, 50139 Florence, Italy.
Mark BordenDepartment of Mechanical Engineering, University of Colorado Boulder, 1111 Engineering Drive, Boulder, Colorado 80309, USA.ORCID s000000022089983X

Funding

Ultrasound Molecular Imaging to Assess Therapeutic ResponseR01CA195051 · NCI · UNIVERSITY OF COLORADO · PI BORDEN, MARK ANDREW, DAYTON, PAUL A · 2015 to 2018
$2.0M
NCI NIH HHS R01 CA195051
6 · The paper itself

Abstract

Microbubble translations driven by ultrasound-induced radiation forces can be beneficial for applications in ultrasound molecular imaging and drug delivery. Here, the effect of size range in microbubble populations on their translations is investigated experimentally and theoretically. The displacements within five distinct size-isolated microbubble populations are driven by a standard ultrasound-imaging probe at frequencies ranging from 3 to 7 MHz, and measured using the multi-gate spectral Doppler approach. Peak microbubble displacements, reaching up to 10 μm per pulse, are found to describe transient phenomena from the resonant proportion of each bubble population. The overall trend of the statistical behavior of the bubble displacements, quantified by the total number of identified displacements, reveals significant differences between the bubble populations as a function of the transmission frequency. A good agreement is found between the experiments and theory that includes a model parameter fit, which is further supported by separate measurements of individual microbubbles to characterize the viscoelasticity of their stabilizing lipid shell. These findings may help to tune the microbubble size distribution and ultrasound transmission parameters to optimize the radiation-force translations. They also demonstrate a simple technique to characterize the microbubble shell viscosity, the fitted model parameter, from freely floating microbubble populations using a standard ultrasound-imaging probe.

Indexed as

Contrast MediaMicrobubblesUltrasonic WavesUltrasonographyViscosityContrast Media

Identifiers

PMID32486824
PMCPMC7205472

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.