Evidence map›Paper›PMID 32482629›Full record

Observational studyThe British journal of general practice : the journal of the Royal College of General Practitioners2020

Accuracy of blood-pressure monitors owned by patients with hypertension (ACCU-RATE study): a cross-sectional, observational study in central England.

James A Hodgkinson, Mei-Man Lee, Siobhan Milner, Peter Bradburn, Richard Stevens, Fd Richard Hobbs, Constantinos Koshiaris, Sabrina Grant, Jonathan Mant, Richard J McManus

Open access · hybridAbstract readObservational Study
In one paragraph

Observational study in The British journal of general practice : the journal of the Royal College of General Practitioners, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 3 pooled it
3.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 3 syntheses or guidelines pooled it, 51 citations in OpenAlex.

  1. Guideline
  2. Guideline
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Article
  11. Article
  12. Article
  13. Article
  14. Quality of Blood Pressure Monitoring During Telehealth Visits for Pregnant Patients at Risk of Preeclampsia.Telemedicine journal and e-health : the official journal of the American Telemedicine Association · 2024
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

James A HodgkinsonInstitute of Applied Health Research, University of Birmingham, Edgbaston.
Mei-Man LeeNuffield professor of primary care health sciences.
Siobhan MilnerInstitute of Applied Health Research, University of Birmingham, Edgbaston.
Peter BradburnInstitute of Applied Health Research, University of Birmingham, Edgbaston.
Richard StevensNuffield professor of primary care health sciences.
Fd Richard HobbsNuffield professor of primary care health sciences.
Constantinos KoshiarisNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford.
Sabrina GrantThree Counties School of Nursing and Midwifery, University of Worcester, Worcester.
Jonathan MantPrimary Care Unit, Strangeways Research Laboratory, Cambridge.
Richard J McManusNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford.
Primary Health Care · QAUniversity of Oxford · GB

Funding

Medical Research Council MC_PC_11004
6 · The paper itself

Abstract

backgroundHome blood-pressure (BP) monitoring is recommended in guidelines and is increasingly popular with patients and health professionals, but the accuracy of patients' own monitors in real-world use is not known.

aimTo assess the accuracy of home BP monitors used by people with hypertension, and to investigate factors affecting accuracy. DESIGN AND

settingCross-sectional, observational study in urban and suburban settings in central England.

methodPatients (

resultsIn total, 251 (76%, 95% confidence interval [95% CI] = 71 to 80%) of 331 tested devices passed all tests (monitors and cuffs), and 86% (CI] = 82 to 90%) passed the static pressure test; deficiencies were, primarily, because of monitors overestimating BP. A total of 40% of testable monitors were not validated. The pass rate on the static pressure test was greater in validated monitors (96%, 95% CI = 94 to 98%) versus unvalidated monitors (64%, 95% CI = 58 to 69%), those retailing for >£10 (90%, 95% CI = 86 to 94%), those retailing for ≤£10 (66%, 95% CI = 51 to 80%), those in use for ≤4 years (95%, 95% CI = 91 to 98%), and those in use for >4 years (74%, 95% CI = 67 to 82%). All in all, 12% of cuffs failed.

conclusionPatients' own BP monitor failure rate was similar to that demonstrated in studies performed in professional settings, although cuff failure was more frequent. Clinicians can be confident of the accuracy of patients' own BP monitors if the devices are validated and ≤4 years old.

Indexed as

Blood Pressure Monitoring, AmbulatoryHypertensionSphygmomanometersBlood PressureBlood Pressure DeterminationCross-Sectional StudiesEnglandHumansaccuracyblood-pressure monitorscalibrationhypertensionprimary health care

Identifiers

PMID32482629
PMCPMC7274541
OpenAlexW3031286444

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.