Evidence map›Paper›PMID 32481266›Full record

Observational studyMedicine2020

Changes in the concentrations of mediators in exhaled breath condensate during cardiac valve replacement under cardiopulmonary bypass and their relations with postoperative acute respiratory distress syndrome.

Jie Song, Lei Yao, Lulin Zhao, Boxiang Du, Lin Liu, Jinliang Chen

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jie SongDepartment of Anesthesiology.
Lei YaoDepartment of Anesthesiology.
Lulin ZhaoDepartment of Anesthesiology.
Boxiang DuDepartment of Anesthesiology.
Lin LiuDepartment of Anesthesiology.
Jinliang ChenDepartment of Respiratory Medicine, The Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China.
Valve (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To investigate the changes in the concentrations of interleukin-6 (IL-6), interleukin-8 (IL-8), tumor necrosis factor-α (TNF-α), and 8-iso-prostaglandin F2α (8-isoPGF2α) in exhaled breath condensate (EBC) in patients undergoing cardiac valve replacement under cardiopulmonary bypass (CPB) and its relationship with postoperative acute respiratory distress syndrome (ARDS).A prospective, case-control study was performed on 55 patients undergoing elective cardiac valve replacement under cardiopulmonary bypass, between November 2017 and May 2019. According to the diagnosis of postoperative ARDS, the patients were divided into ARDS group and control group. We compared the clinical characteristics, outcomes, respiratory mechanics, oxygenation parameters, and mediators in the 2 groups immediately after tracheal intubation (T1), at the end of CPB (T2), and 2 hours (T3) and 6 hours (T4) after CPB, and calculated the receiver operating characteristic curve (ROC), sensitivity, and specificity of the corresponding mediators.ARDS occurred in 29 patients after CPB. The ARDS group exhibited prolonged postoperative ventilator support, time to extubation, length of stay in the ICU, and postoperative length of stay. The peak airway pressure (Ppeak) and plat airway pressure (Pplat) at T4 were higher in the ARDS group compared with the control group. The alveolar-arterial oxygen partial pressure [P(A-a)O2] and respiratory index (RI) were higher and PaO2/FiO2 was lower in the ARDS group at T2-4 compared with the control group. The levels of EBC and serum mediators in the ARDS group were significantly higher at T2-4 compared with those in the control group. All the mediators in EBC were correlated significantly with those in the serum in the ARDS group (r = 0.7314, 0.898, 0.8386, 0.792) and control group (r = 0.6093, 0.8524, r = 0.7828, r = 0.6575) (P < .001). Meanwhile, the area under the curve (AUC) of IL-8 in EBC was significantly lower at T2 and the AUC of IL-6 in EBC was significantly higher at T4 than in serum (P < .05). In addition, all of the mediators in EBC had a certain accuracy in diagnose of postoperative ARDS.EBC analysis could be used to predict the high incidence of ARDS after cardiac valve replacement under CPB.

Indexed as

ExhalationAdultAgedAged, 80 and overCardiopulmonary BypassCase-Control StudiesFemaleHeart Valve Prosthesis ImplantationHumansInterleukin-6Interleukin-8Length of StayMaleMiddle AgedPostoperative PeriodProspective StudiesCXCL8 protein, humanInterleukin-6Interleukin-8Tumor Necrosis Factor-alpha

Identifiers

PMID32481266
PMCPMC7249883
OpenAlexW3032240858

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.