Effect of testing procedures on gait speed measurement: A systematic review.

Anna K Stuck, Madeleine Bachmann, Pia Füllemann, Karen R Josephson, Andreas E Stuck

Abstract readSystematic Review
In one paragraph

Synthesis in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Gait differences between COPD and healthy controls: systematic review and meta-analysis.European respiratory review : an official journal of the European Respiratory Society · 2024
    Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Prevention of Sarcopenia.Advances in experimental medicine and biology · 2025
    Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anna K StuckDepartment of Geriatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.ORCID 0000-0001-8322-5501
Madeleine BachmannDepartment of Geriatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Pia FüllemannDepartment of Geriatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Karen R JosephsonGeriatric Research Education & Clinical Center, Veterans Administration Greater Los Angeles Healthcare System, Los Angeles, California, United States of America.
Andreas E StuckDepartment of Geriatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlthough gait speed is a widely used measure in older people, testing methods are highly variable. We conducted a systematic review to investigate the influence of testing procedures on resulting gait speed.

methodsWe followed the PRISMA checklist for this systematic review. Two independent reviewers screened Pubmed and Embase for publications on pairwise comparisons of testing procedures of usual gait speed. Descriptives were abstracted from the included publications using a predefined extraction tool by two independent reviewers. We defined the cut-off for the minimal clinically imporant diffence in gait speed as 0.1 m/sec.

resultsOf a total of 2109 records identified for screening, 29 reports on 53 pairwise comparisons were analyzed. The median (range) difference in gait speed for dynamic versus static start was 0.06 (-0.02 to 0.35) m/sec (14 reports); for longer versus shorter test distance 0.04 (-0.05 to 0.23) m/sec (14 reports); for automatic versus manual timing 0.00 (-0.05 to 0.07) m/sec (12 reports), for hard versus soft surfaces -0.11 (-0.18 to 0.08) m/sec (six reports), and electronic walkways versus usual walk test 0.04 (-0.08 to 0.14) m/sec (seven reports), respectively. No report compared the effect of finishing procedures.

conclusionsThe type of starting procedure, the length of the test distance, and the surface of the walkway may have a clinically relevant impact on measured gait speed. Manual timing resulted in statistically significant differences of measured gait speed as compared to automatic timing, but was below the level of clinical importance. These results emphasize that it is key to use a strictly standardized method for obtaining a reliable and valid measurement of gait speed.