Validation and comparison of four handheld tonometers in normal ex vivo canine eyes.

Andrea L Minella, Julie A Kiland, Shawna Gloe, Gillian J McLellan

Open access · greenAbstract readComparative StudyValidation Study
In one paragraph

Article in Veterinary ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Evaluation of the iFalconBMC veterinary research · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Andrea L MinellaDepartment of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, WI, USA.
Julie A KilandDepartment of Ophthalmology & Visual Sciences, University of Wisconsin, Madison, WI, USA.ORCID https://orcid.org/0000-0002-9019-2346
Shawna GloeDepartment of Ophthalmology & Visual Sciences, University of Wisconsin, Madison, WI, USA.
Gillian J McLellanDepartment of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, WI, USA.
University of Wisconsin–Madison · US

Funding

UW Vision Research Core - Administrative CoreP30EY016665 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI Donna M Peters · 2005 to 2026
$12.6M
NEI NIH HHS P30 EY016665NEI NIH HHS P30 EY16665Research to Prevent Blindness
6 · The paper itself

Abstract

objectivesTo determine the accuracy and precision of the Icare ANIMALS & PROCEDURES: The anterior chambers of six normal dog eyes were cannulated ex vivo. IOP was measured with the TONOVET (TV01), TONOVET Plus, Tono-Pen Vet™, and Tono-Pen AVIA Vet™ at manometric IOPs ranging from 5 to 70 mm Hg. Data were analyzed by linear regression, ANOVA and Bland-Altman plots. A P value ≤ .05 was considered significant.

resultsIntraocular pressure values obtained using the TONOVET Plus and TV01 were significantly more accurate than with the Tono-Pen VET and Tono-Pen AVIA Vet, particularly at higher IOPs (30-70 mm Hg). Accuracy was not significantly different between any of the devices in the low to normal physiologic IOP range (5-25 mm Hg). Level of precision was high for all devices, though the TONOVET Plus was more precise than the Tono-Pen Vet in the 5-25 mmHg range and the TV01 was more precise than the Tono-Pen AVIA Vet over the whole IOP range.

conclusionsAll devices underestimated IOP, particularly at higher pressures. Rebound tonometers were more accurate over the full range of IOP tested and in the high IOP range; however, there were no significant differences in accuracy among devices in the physiologic IOP range. All tonometers can provide clinically useful IOP readings in dogs, but rebound and applanation tonometers should not be used interchangeably.

Indexed as

DogsAnimalsFemaleIntraocular PressureMaleReference ValuesReproducibility of ResultsTonometry, Ocularapplanation tonometerdogintraocular pressuremanometryrebound tonometer

Identifiers

PMID32478941
PMCPMC8321415
OpenAlexW3031828497

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.