ArticleThe Journal of innovations in cardiac rhythm management2019
Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor.
Article in The Journal of innovations in cardiac rhythm management, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Cardiac Monitoring: Then and Now.The Journal of innovations in cardiac rhythm management · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The association between ventricular arrhythmia (VA) burden or defibrillator therapy and pulmonary artery pressure (PAP) has not been characterized in an ambulatory setting; thus, we sought in the present research to determine the relationship between ambulatory PAP and VA burden. A retrospective cohort study involving patients with an implantable cardiac defibrillator and CardioMEMS™ PAP sensor (Abbott Laboratories, Chicago, IL, USA) both transmitting remotely into the Merlin.net™ patient care network (Abbott Laboratories, Chicago, IL, USA) was conducted. VA and therapy burden in the six months following sensor implant were stratified by the baseline mean PAP. Patients with PAPs of 25 mmHg to 35 mmHg and those with PAPs of 35 mmHg or more were compared with individuals with PAPs of less than 25 mmHg. The change in VA burden was reported using the averaged mean PAP reduction during the first three months. A total of 162 patients aged 69.4 years ± 10.9 years were included (74% male) with a baseline mean PAP of 36.2 mmHg ± 10.4 mmHg. Twenty patients with a baseline mean PAP of less than 25 mmHg had no VAs over six months. For 61 patients with a baseline mean PAP of between 25 mmHg and 35 mmHg, the annualized number of days with ventricular tachycardia (VT)/ventricular fibrillation (VF) was 1.65/patient-year (p < 0.001), with 8% of patients having VT/VF events. For 81 patients with a baseline mean PAP of 35 mmHg or more, 19% of patients had a VT/VF event and an annualized number of days with VT/VF events of 1.45/patient-year (p < 0.001). When analyzing the treatment effect, a reduction of 3 mmHg or more in mean PAP over three months reduced arrhythmia burden over the next three months as compared with in patients without such an improvement. In conclusion, it is indicated that VAs are associated with high PAPs, and a reduction in PAP may lead to a reduction in VAs in real-world ambulatory patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.