Evidence map›Paper›PMID 32477074›Full record

ArticleFrontiers in neuroanatomy2020

High-Resolution Episcopic Imaging for Visualization of Dermal Arteries and Nerves of the Auricular Cymba Conchae in Humans.

Babak Dabiri, Stefan Kampusch, Stefan H Geyer, Van Hoang Le, Wolfgang J Weninger, Jozsef Constantin Széles, Eugenijus Kaniusas

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroanatomy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Auricular vagus nerve stimulator for closed-loop biofeedback-based operation.Analog integrated circuits and signal processing · 2022
    Article
  10. Article
  11. Article
  12. Article
  13. Understanding Diabetic Neuropathy: Focus on Oxidative Stress.Oxidative medicine and cellular longevity · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Babak DabiriInstitute of Electrodynamics, Microwave and Circuit Engineering, Vienna University of Technology, Vienna, Austria.
Stefan KampuschInstitute of Electrodynamics, Microwave and Circuit Engineering, Vienna University of Technology, Vienna, Austria.
Stefan H GeyerDivision of Anatomy, MIC, Medical University of Vienna, Vienna, Austria.
Van Hoang LeInstitute of Electrodynamics, Microwave and Circuit Engineering, Vienna University of Technology, Vienna, Austria.
Wolfgang J WeningerDivision of Anatomy, MIC, Medical University of Vienna, Vienna, Austria.
Jozsef Constantin SzélesDepartment for Vascular Surgery, University Clinic for Surgery, Medical University of Vienna, Vienna, Austria.
Eugenijus KaniusasInstitute of Electrodynamics, Microwave and Circuit Engineering, Vienna University of Technology, Vienna, Austria.
TU Wien · ATMedical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Therapeutic applications of auricular vagus nerve stimulation (VNS) have drawn recent attention. Since the targeted stimulation process and parameters depend on the electrode-tissue interaction, the lack of structural anatomical information on innervation and vascularization of the auricle restrain the current optimization of stimulation paradigms. For the first time, we employed high-resolution episcopic imaging (HREM) to generate histologic volume data from donated human cadaver ears. Optimal parameters for specimen preparation were evaluated. Anatomical 3D vascular and nerve structures were reconstructed in one sample of an auricular cymba conchae (CC). The feasibility of HREM to visualize anatomical structures was assessed in that diameters, occupied areas, volumes, and mutual distances between auricular arteries, nerves, and veins were registered. The selected region of CC (3 × 5.5 mm) showed in its cross-sections 21.7 ± 2.7 (mean ± standard deviation) arteries and 14.66 ± 2.74 nerve fibers. Identified nerve diameters were 33.66 ± 21.71 μm, and arteries had diameters in the range of 71.58 ± 80.70 μm. The respective occupied area showed a share of, on average, 2.71% and 0.3% for arteries and nerves, respectively, and similar volume occupancy for arteries and nerves. Inter-centroid minimum distance between arteries and nerves was 274 ± 222 μm. The density of vessels and nerves around a point within CC on a given grid was assessed, showing that 50% of all vessels and nerves were found in a radial distance of 1.6-1.8 mm from any of these points, which is strategically relevant when using stimulation needles in the auricle for excitation of nerves. HREM seems suitable for anatomical studies of the human ear. A 3D model of CC was established in the micrometer scale, which forms the basis for future optimization of the auricular VNS. Obviously, the presented single cadaver study needs to be validated by additional anatomical data on the innervation and vascularization of the auricle.

Indexed as

3D modelingauricular vagus nervecymba conchaeelectrical stimulationepiscopic imaging

Identifiers

PMID32477074
PMCPMC7236887
OpenAlexW3025371979

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.