Evidence map›Paper›PMID 32476729›Full record

ArticleMicrosystem technologies : sensors, actuators, systems integration2020

Parametric study of 3D printed microneedle (MN) holders for interstitial fluid (ISF) extraction.

Robert M Taylor, Dilendra Maharjan, Fernando Moreu, Justin T Baca

Abstract read
In one paragraph

Article in Microsystem technologies : sensors, actuators, systems integration, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. 3D printed microneedles: revamping transdermal drug delivery systems.Drug delivery and translational research · 2025
    Review
  3. Article
  4. Article
  5. Review
  6. Microneedle-based bioassays.Nanoscale advances · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Robert M Taylor *1Department of Emergency Medicine, The University of New Mexico, MSC11 6025, Albuquerque, NM 87131 USA.
Dilendra Maharjan *2Department of Civil, Construction and Environmental Engineering, Courtesy Appointment, The University of New Mexico, Centennial Engineering Center 3056, MSC01 1070, Albuquerque, NM 87131 USA.
Fernando Moreu2Department of Civil, Construction and Environmental Engineering, Courtesy Appointment, The University of New Mexico, Centennial Engineering Center 3056, MSC01 1070, Albuquerque, NM 87131 USA.
Justin T Baca1Department of Emergency Medicine, The University of New Mexico, MSC11 6025, Albuquerque, NM 87131 USA.ORCID 0000-0002-9335-5200

Funding

UNM HSC Clinical and Translational Science CenterUL1TR001449 · NCATS · UNIVERSITY OF NEW MEXICO HEALTH SCIS CTR · PI CAMPEN, MATTHEW J, PANDHI, NANCY · 2015 to 2024
$36.9M
University of New Mexico Clinical and Translational Science CenterKL2TR001448 · NCATS · UNIVERSITY OF NEW MEXICO HEALTH SCIS CTR · PI CANNON, JUDY LIN · 2015 to 2024
$3.5M
Washington University Institute of Clinical and Translational SciencesTL1TR000449 · NCATS · WASHINGTON UNIVERSITY · PI EVANOFF, BRADLEY A · 2012 to 2016
$2.5M
Center for Clinical and Translational ScienceTL1TR000049 · NCATS · UNIVERSITY OF ILLINOIS AT CHICAGO · PI AZAR, DIMITRI T, MERMELSTEIN, ROBIN J. · 2012 to 2014
$358k
NCATS NIH HHS KL2 TR001448NCATS NIH HHS TL1 TR000049NCATS NIH HHS TL1 TR000449NCATS NIH HHS UL1 TR001449
6 · The paper itself

Abstract

The need for novel, minimally invasive diagnostic, prognostic, and therapeutic biomedical devices has garnered increased interest in recent years. Microneedle (MN) technology has stood out as a promising new method for drug delivery, as well as extraction of interstitial fluid (ISF). ISF comprises a large portion of the extracellular fluid in living organisms yet remains inadequately characterized for clinical applications. Current MN research has focused on the fabrication of needles with different materials like silicone, carbon, and metals. However, little effort has been put forth into improving MN holders and patches that can be used with low cost MNs, which could effectively change how MNs are attached to the human body. Here, we describe different 3D-printed MN holders, printed using an MJP Pro 2500 3D printer, and compare the ISF extraction efficiencies in CD Hairless rats. We varied design parameters that may affect the skin-holder interface, such as throat thickness, tip curvature, and throat diameter. MN arrays, with insertion depths of 1500 μm, had extraction efficiencies of 0.44 ± 0.35, 0.85 ± 0.64, 0.32 ± 0.21, or 0.44 ± 0.46 µl/min when designed with flat, concave, convex, or bevel profile geometries, respectively. Our results suggest ISF extraction is influenced by MN holder design parameters and that a concave tip design is optimal for extracting ISF from animals. The future direction of this research aims to enable a paradigm in MN design that maximizes its efficiency and engineering performance in terms of volume, pressure, and wearability, thereby automatizing usage and reducing patient intervention to ultimately benefit remote telemedicine.

Identifiers

PMID32476729
PMCPMC7238769

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.