Evidence map›Paper›PMID 32476675›Full record

ArticleJournal of dynamic systems, measurement, and control2020

Observer-Based Deconvolution of Deterministic Input in Coprime Multichannel Systems With Its Application to Noninvasive Central Blood Pressure Monitoring.

Zahra Ghasemi, Woongsun Jeon, Chang-Sei Kim, Anuj Gupta, Rajesh Rajamani, Jin-Oh Hahn

Open access · bronzeAbstract read
In one paragraph

Article in Journal of dynamic systems, measurement, and control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Zahra GhasemiDepartment of Mechanical Engineering, University of Maryland, 2107B Glenn L. Martin Hall, College Park, MD 20742.
Woongsun JeonDepartment of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, MN 55455.
Chang-Sei KimSchool of Mechanical Engineering, Chonnam National University, 77 Yongbong-Ro, Buk-Gu, Gwangju 61186, South Korea.
Anuj GuptaDepartment of Medicine, University of Maryland Medical Center, 110 South Paca Street, 7th Floor, Baltimore, MD 21201.
Rajesh RajamaniDepartment of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, MN 55455.
Jin-Oh HahnDepartment of Mechanical Engineering, University of Maryland, 2104C Glenn L. Martin Hall, College Park, MD 20742.
University of Maryland, College Park · USUniversity of Minnesota · USChonnam National University · KRUniversity of Maryland, Baltimore · US

Funding

Unobtrusive and Affordable Blood Pressure Monitoring Via Pulse Transit TimeU01EB018818 · NIBIB · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI MUKKAMALA, RAMAKRISHNA · 2014 to 2018
$3.4M
NIBIB NIH HHS U01 EB018818
6 · The paper itself

Abstract

Estimating central aortic blood pressure (BP) is important for cardiovascular (CV) health and risk prediction purposes. CV system is a multichannel dynamical system that yields multiple BPs at various body sites in response to central aortic BP. This paper concerns the development and analysis of an observer-based approach to deconvolution of unknown input in a class of coprime multichannel systems applicable to noninvasive estimation of central aortic BP. A multichannel system yields multiple outputs in response to a common input. Hence, the relationship between any pair of two outputs constitutes a hypothetical input-output system with unknown input embedded as a state. The central idea underlying our approach is to derive the unknown input by designing an observer for the hypothetical input-output system. In this paper, we developed an unknown input observer (UIO) for input deconvolution in coprime multichannel systems. We provided a universal design algorithm as well as meaningful physical insights and inherent performance limitations associated with the algorithm. The validity and potential of our approach were illustrated using a case study of estimating central aortic BP waveform from two noninvasively acquired peripheral arterial pulse waveforms. The UIO could reduce the root-mean-squared error (RMSE) associated with the central aortic BP by up to 27.5% and 28.8% against conventional inverse filtering (IF) and peripheral arterial pulse scaling techniques.

Identifiers

PMID32476675
PMCPMC7247534
OpenAlexW3022763400

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.