Evidence map›Paper›PMID 32471516›Full record

ArticleJournal of nanobiotechnology2020

Nano-copper enhanced flexible device for simultaneous measurement of human respiratory and electro-cardiac activities.

Li Wang, Feng Zhang, Kechao Lu, Mohammed Abdulaziz, Chao Li, Chongyu Zhang, Jun Chen, Yunlun Li

Open access · goldAbstract read
In one paragraph

Article in Journal of nanobiotechnology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Nanosized copper particles induced mesangial cell toxicity via the autophagy pathway.Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologica · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Li WangAdvanced Micro and Nanoinstruments Center (AMNC), School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China. liwang@qlu.edu.cn.ORCID http://orcid.org/0000-0002-5166-0397
Feng ZhangAdvanced Micro and Nanoinstruments Center (AMNC), School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China.
Kechao LuAdvanced Micro and Nanoinstruments Center (AMNC), School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China.
Mohammed AbdulazizDepartment of Mechanical and Process Engineering, University of Duisburg Essen, Forsthausweg, 247057, Germany.
Chao LiExperimental Center, Shandong University of Traditional Chinese Medicine, Jinan, 250355, China.
Chongyu ZhangThe Second Affiliated Hospital, Guangzhou Medical University, Guangzhou, 510260, China.
Jun ChenAdvanced Micro and Nanoinstruments Center (AMNC), School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China. chenjun@qlu.edu.cn.
Yunlun LiExperimental Center, Shandong University of Traditional Chinese Medicine, Jinan, 250355, China. yunlun.lee@hotmail.com.
Qilu University of Technology · CNShandong University of Traditional Chinese Medicine · CNSecond Affiliated Hospital of Guangzhou Medical University · CNUniversity of Duisburg-Essen · DE

Funding

National Science and Technology Planning Project 61901239QingChuang science and technology plan of colleges and universities in Shandong Province 2019KJB009Taishan scholar young expert tsqn201812087
6 · The paper itself

Abstract

backgroundDysfunction of human respiratory and electro-cardiac activities could affect the ability of the heart to pump blood and the lungs to inhale oxygen. Thus, a device could simultaneously measure electro-cardiac signal and respiratory pressure could provide vital signs for predicting early warning of cardio-pulmonary function-related chronic diseases such as cardiovascular disease, and respiratory system disease.

resultsIn this study, a flexible device integrated with piezo-resistive sensing element and voltage-sensing element was developed to simultaneously measure human respiration and electro-cardiac signal (including respiratory pressure, respiration frequency, and respiration rhythm; electro-cardio frequency, electro-cardio amplitude, and electro-cardio rhythm). When applied to the measurement of respiratory pressure, the piezo-resistive performance of the device was enhanced by nano-copper modification, which detection limitation of pressure can reduce to 100 Pa and the sensitivity of pressure can achieve to 0.053 ± 0.00079 kPa

conclusionThis paper presents a flexible device for the simultaneous detection of human respiration and cardiac electrical activity. To avoid interference between the two signals, the layout of the electrode and the strain sensor was optimized by FEA simulation analysis. To improve the piezo-resistive sensitivity and bio-electric capturing capability of the device, a feather-shaped nano-copper was modified onto the surface of carbon fiber. The operation simplicity, compact size, and portability of the device open up new possibilities for multi-parameter monitoring.

Indexed as

RespirationCopperElectrocardiographyElectrodesHumansMetal NanoparticlesMonitoring, PhysiologicSignal Processing, Computer-AssistedSignal-To-Noise RatioCopperElectro-cardiac signalsFlexible deviceNano-copperRespirationSimultaneous measurement

Identifiers

PMID32471516
PMCPMC7257177
OpenAlexW3031218236

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.