Evidence map›Paper›PMID 32468290›Full record

ArticleMikrochimica acta2020

Amperometric determination of hydrazine using a CuS-ordered mesoporous carbon electrode.

G Srinidhi, S Sudalaimani, K Giribabu, S J Sardhar Basha, C Suresh

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Electrochemical Sensor Based on ZnFeNanomaterials (Basel, Switzerland) · 2022
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

G SrinidhiDepartment of Nanoscience and Nanotechnology, Anna University Regional Campus, Coimbatore, Tamil Nadu, 641 046, India.
S SudalaimaniElectrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India.
K GiribabuElectrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India. giribabuk@cecri.res.in.ORCID 0000-0002-7925-2133
S J Sardhar BashaDepartment of Nanoscience and Nanotechnology, Anna University Regional Campus, Coimbatore, Tamil Nadu, 641 046, India.
C SureshElectrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India. csuresh@cecri.res.in.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An electrocatalytic sensor for hydrazine using copper sulfide-ordered mesoporous carbon (CuS-OMC) is described. A facile solvothermal synthetic strategy was adopted for CuS-OMC and the ordered mesoporous carbon was obtained through nanocasting method. The synthesized CuS-OMC was characterized using microscopic and spectrochemical techniques. CuS-OMC was immobilized on GCE and evaluated for its electrochemical sensing of hydrazine using cyclic voltammetry and amperometry. CuS-OMC modified GCE exhibited better hydrazine sensing at an optimized pH 7.4 in terms of oxidation potential and current compared with that of GCE, CuS, and OMC. The observed sensing performance of CuS-OMC was attributed to the presence of Cu (I/II) in CuS dispersed in OMC which acts as an electrocatalytic center for the sensing of hydrazine. Amperometry under optimized experimental condition with an applied potential of 270 mV was employed to obtain a linear calibration plot in the range 0.25 to 40 μM (R

Indexed as

Copper sulfideElectrocatalytic sensorHydrazineMesoporous carbon

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.