Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.
- High variability exists in 3D leg alignment analysis, but underlying principles that might lead to agreement on a universal framework could be identified: A systematic review.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Pooled it
- Statistical shape modeling of the proximal femur bone for hip implant design optimization.Scientific reports · 2026Article
- A centroid iterative method for fitting the femoral neck axis in rotational osteotomy: a finite element analysis and biomechanical investigation.Journal of hip preservation surgery · 2025Article
- Consistency of 3D reconstruction measurements of lower limb torsion at different segments with the CT gold standard.Scientific reports · 2025Article
- Article
- Intraoperative estimation of natural femoral anteversion from proximal femoral osseous orientation during total hip arthroplasty.Journal of orthopaedic surgery and research · 2024Article
- Gender differences in ethmoid sinus morphology_ 3D reconstruction of computed tomographic images.BMC medical imaging · 2024Article
- Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures.Orthopaedic surgery · 2024Article
- A guide to facilitate the creation of a femoral tunnel for arthroscopic ligamentum teres reconstruction: a three-dimensional computed tomography study.Journal of hip preservation surgery · 2024Article
- The quest for optimal femoral torsion angle measurements: a comparative advanced 3D study defining the femoral neck axis.Journal of experimental orthopaedics · 2023Article
- Triangular Mechanical Structure of the Proximal Femur.Orthopaedic surgery · 2022Article
- The oblique triangle configuration of three parallel screws for femoral neck fracture fixation using computer-aided design modules.Scientific reports · 2022Article
- Innovative Design Methodology for Patient-Specific Short Femoral Stems.Materials (Basel, Switzerland) · 2022Article
- Prediction of osteoporosis from proximal femoral cortical bone thickness and Hounsfield unit value with clinical significance.Frontiers in surgery · 2022Article
- Automated Morphometric Analysis of the Hip Joint on MRI from the German National Cohort Study.Radiology. Artificial intelligence · 2021Article
- Accuracy of CT for measuring femoral neck anteversion in children with developmental dislocation of the hip verified using 3D printing technology.Journal of orthopaedic surgery and research · 2021Article
- The Oval-like Cross-section of Femoral Neck Isthmus in Three-dimensional Morphological Analysis.Orthopaedic surgery · 2021Article
- Morphological Measurement of the Femoral Anterior Bow in Chinese Population Based on Three-Dimensional Computed Tomography.BioMed research international · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
backgroundThe femoral neck torsion angle (FNTA) is an important but often neglected parameter in assessments of the anatomical morphology of the femoral neck, which is often confused with the femoral neck anteversion angle (FNAA) in the current literature. Currently, the measurement methods reported in the literature all adopt the naked eye or two-dimensional (2D) visualization method, and the measurement parameters and details are not clearly defined. The objection of this research was to provide a reliable 3D method for determining the femoral neck axis, to improve the measurement method of the FNTA, and to analyze the anatomical and clinical significance of the results.
methodsComputed tomography (CT) data of 200 patients who received a lower extremity CT angiography examination were selected, and the bilateral femurs were reconstructed with three dimensional CT (3D CT). First, the 3D axis of the femoral neck was built. Second, the long axis of the cross section the femoral neck isthmus (FNI) and femoral neck basilar part (FNB) were confirmed by the "inertia axes" method, and the plane consisting of the long axis of the cross-section and the center of the femoral head was defined as the long axial plane. Third, the coronal plane of the proximal femur was determined through the long axis of the proximal femur and the femoral coronal. Finally, the FNTAs (the angles between the long axial planes and the coronal plane of the proximal femur) of FNI and FNB were measured. The size of FNTA was compared between the sexes and sides and different locations, the correlation between the parameters and age, height, and weight were evaluated.
resultsThe difference in FNTA was statistically significant between the isthmus and the basilar part (isthmus 30.58 ± 8.90° vs. basilar part 23.79 ± 3.98°; p < 0.01). Significant difference in the FNTA was observed between the sexes (males 31.99 ± 9.25° vs. females 27.49 ± 7.19°; p < 0.01). The increase in FNTA from the basilar part to the isthmus was 6.79 ± 8.06°, and the male (7.87 ± 8.57°) was greater than the female (4.44 ± 6.23°, p < 0.01). However, no significant difference in the values was observed between sides. Height exerted the greatest effect on the FNTA according to the correlation analysis (r = 0.255, p< 0.001).
conclusionsThis study found a reliable 3D method for the determination of the femoral neck axis improved the measurement method of the FTNTA and made it more accurate and repeatable. The results provided a methodological basis and theoretical support for the research and development of internal fixation device for femoral neck fracture and the spatial configuration of implants in treatment. And the optimal opening point of the femoral medullary cavity was recommended to locate at the posterior position of the top of the femoral neck cross-section during hip replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.