Evidence map›Paper›PMID 32455568›Full record

ArticleJournal of clinical medicine2020

Assessment of Measurement Reliability for the IPN Test in Cardiac Patients.

Łukasz Oleksy, Agnieszka Skiba, Iwona Sulowska, Marcin Trębowicz, Bartosz Rukasz, Artur Stolarczyk, Joanna Zyznawska, Anna Mika

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 93% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 1 country.

Łukasz OleksyPhysiotherapy and Sports Centre, Rzeszow University of Technology, 35-959 Rzeszow, Poland.ORCID 0000-0002-0589-0554
Agnieszka SkibaInstitute of Clinical Rehabilitation, University of Physical Education in Krakow, 31-571 Krakow, Poland.ORCID 0000-0001-9218-6153
Iwona SulowskaInstitute of Clinical Rehabilitation, University of Physical Education in Krakow, 31-571 Krakow, Poland.ORCID 0000-0003-1025-0508
Marcin TrębowiczMaria Curie-Sklodowska University Branch in Puławy, 24-100 Puławy, Poland.
Bartosz RukaszMilitary Clinical Hospital with Outpatient Clinic, 20-049 Lublin, Poland.
Artur StolarczykOrthopaedic and Rehabilitation Department, Medical University of Warsaw, 02-091 Warsaw, Poland.
Joanna ZyznawskaFaculty of Health Sciences, Department of Physiotherapy, Jagiellonian University Medical College Krakow, 31-008 Krakow, Poland.ORCID 0000-0002-3044-3422
Anna MikaInstitute of Clinical Rehabilitation, University of Physical Education in Krakow, 31-571 Krakow, Poland.ORCID 0000-0002-4366-5091
University School of Physical Education in Kraków · PL1 Military Clinical Hospital with Outpatient Clinic · PLJagiellonian University · PLMaria Curie-Skłodowska University · PLMedical University of Warsaw · PLRzeszów University of Technology · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiological diagnostics use maximal and submaximal tests with increasing load. Maximal stress tests are currently considered the gold standard. The Institut für Prävention und Nachsorge, Cologne (IPN) test may be an alternative when maximal patient load is not indicated. The universality of the test is well-documented in sport, but the reliability of this test is unknown. The aim of this study was to assess between-trial and between-day reliability for parameters assessed by the IPN stress test in cardiological patients.: In a study of 24 patients aged 39 to 79 years with cardiovascular diseases, the IPN cycle ergometer short test was performed (submaximal performance test). The reliability of heart rate, systolic and diastolic pressure, absolute power at submaximal load, relative performance at submaximal load and target heart rate were assessed. Good (Interclass Correlation Coefficient (ICC) values ranged from 0.832 to 0.894) and excellent (ICC values ranged from 0.904 to 0.969) between-trial reliability was noted. Between-day reliability was good (ICC values from 0.777 to 0.895) and excellent (ICC values from 0.922 to 0.950). The obtained results suggest that the IPN test may be a reliable tool for use in the assessment of cardiological patients, avoiding the implementation of maximal efforts when excessive patient load is not recommended.

Indexed as

cardiac rehabilitationIPN testperformance testsubmaximal tests

Identifiers

PMID32455568
PMCPMC7290293
OpenAlexW3028231463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.