ArticleCureus2020
Safety and Feasibility of Performing Fenestrated Endovascular Abdominal Aneurysm Repair Using a Portable C-arm Without Fusion Technology: A Single-Center Experience.
Article in Cureus, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective Most centers performing fenestrated endovascular aneurysm repair (F-EVAR) use hybrid rooms with fusion technology for mapping. We present our experience of successfully performing F-EVAR using C-arm without fusion technology. Methods During the period of January 2016 to October 2018, data were collected from a prospectively maintained F-EVAR database at our tertiary care institute. The primary endpoint was technical success, and the secondary outcomes measured were short- and midterm clinical success (both defined by the Society for Vascular Surgery reporting standards), blood loss, radiation dose, operative time, postoperative endoleaks, aneurysm rupture, endograft patency, and complications. Results We performed 11 F-EVARs during the study period in five (45.5%) males and six (54.5%) females, with a mean age of 75+8 years. All procedures were performed under general anesthesia using OEC 9900 Elite Mobile C-arm (GE Healthcare, Chicago, IL, USA) without the use of fusion technology. Three patients had planned preoperative open procedures for access due to prior cutdown or bypass. Technical success was achieved in all 11 (100%) cases. The mean length of stay was 5+2 days, and the mean follow-up was 7.5+6.5 months. The mean procedure time was 301+167 minutes, and the mean blood loss was 361+233 mL. Mean fluoroscopy time was 72+31 minutes, and the mean radiation exposure time was 2,160+930 mGy. No patients required intraoperative transfusion. Thirty-day (short term) clinical success was achieved in 10 (90.0%), cases whereas six-month (midterm) clinical success was achieved in 7 (77.7%) patients. Branch vessel patency was 11 (100%) at 30 days and 9 (81.8%) at six months, and primary endograft patency was 100% (11) at six months. We had no perioperative mortality or major adverse cardiac event at 30 days. Thirty-day postoperative morbidity included readmission for pulmonary edema from cardiac failure in one patient. Two patients had clinically insignificant silent cardiac enzyme elevation. Three patients had re-interventions performed during the mean follow-up period. Two patients developed renal stent thrombosis resulting in renal insufficiency, which is defined as an increase in creatinine concentration ≥0.5 mg/dL, without the need for dialysis. One type II endoleak was identified postoperatively that required trans-lumbar embolization. No type I or III endoleaks were identified during the study period. Asymptomatic common femoral artery thrombosis was seen on follow-up imaging in one patient. Conclusions We conclude that F-EVAR can be safely performed using C-arm without the use of fusion technology. Its utility can be expanded to centers with appropriate skill set but no hybrid technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.