Evidence map›Paper›PMID 32454886›Full record

ArticleComputational and mathematical methods in medicine2020

Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case.

Adi A Basri, Mohammad Zuber, Ernnie I Basri, Muhammad S Zakaria, Ahmad F A Aziz, Masaaki Tamagawa, Kamarul A Ahmad

Open access · hybridAbstract readCase Reports
In one paragraph

Article in Computational and mathematical methods in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.2field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Diversity, Lifestyle, Genomics, and Their Functional Role ofJournal of fungi (Basel, Switzerland) · 2023
    Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Adi A BasriDepartment of Aerospace Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID https://orcid.org/0000-0001-6606-4582
Mohammad ZuberDepartment of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID https://orcid.org/0000-0002-5790-5009
Ernnie I BasriDepartment of Aerospace Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID https://orcid.org/0000-0001-9072-9476
Muhammad S ZakariaFakulti Kejuruteraan Mekanikal, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya 76100, Durian Tunggal, Melaka, Malaysia.ORCID https://orcid.org/0000-0002-5364-7452
Ahmad F A AzizDepartment of Medicine, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID https://orcid.org/0000-0003-1460-5687
Masaaki TamagawaDepartment of Biological Function and Engineering, Kyushu Institute of Technology, Kitakyushu, Japan.ORCID https://orcid.org/0000-0002-5938-346X
Kamarul A AhmadDepartment of Aerospace Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID https://orcid.org/0000-0002-4065-4266
Universiti Putra Malaysia · MYKyushu Institute of Technology · JPManipal Academy of Higher Education · INTechnical University of Malaysia Malacca · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.

Indexed as

AgedAortic ValveAortic Valve StenosisBlood Flow VelocityComputational BiologyComputer SimulationHeart Valve ProsthesisHemodynamicsHemorheologyHumansHydrodynamicsImaging, Three-DimensionalMaleModels, CardiovascularPatient-Specific ModelingProsthesis Design

Identifiers

PMID32454886
PMCPMC7219000
OpenAlexW3022036281

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.