Evidence map›Paper›PMID 32454468›Full record

ArticleJournal of neural engineering2020

Sputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes.

Bo Fan, Alexander V Rodriguez, Daniel G Vercosa, Caleb Kemere, Jacob T Robinson

Abstract read
In one paragraph

Article in Journal of neural engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Graphene Biointerface for Cardiac Arrhythmia Diagnosis and Treatment.Advanced materials (Deerfield Beach, Fla.) · 2023
    Article
  6. Flexible IrOActa biomaterialia · 2023
    Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant.IEEE transactions on biomedical circuits and systems · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bo FanDepartment of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States of America. Co-first authors.
Alexander V Rodriguez
Daniel G Vercosa
Caleb Kemere
Jacob T Robinson

Funding

Fluidic microdrives for minimally invasive actuation of flexible electrodesR21EY028397 · NEI · RICE UNIVERSITY · PI ROBINSON, JACOB T. · 2017 to 2018
$475k
NEI NIH HHS R21 EY028397
6 · The paper itself

Abstract

objectiveRecording electrical activity from individual cells in vivo is a key technology for basic neuroscience and has growing clinical applications. To maximize the number of independent recording channels as well as the longevity, and quality of these recordings, researchers often turn to small and flexible electrodes that minimize tissue damage and can isolate signals from individual neurons. One challenge when creating these small electrodes, however, is to maintain a low interfacial impedance by applying a surface coating that is stable in tissue and does not significantly complicate the fabrication process. APPROACH: Here we use a high-pressure Pt sputtering process to create low-impedance electrodes at the wafer scale using standard microfabrication equipment. MAIN

resultsWe find that direct-sputtered Pt provides a reliable and well-controlled porous coating that reduces the electrode impedance by 5-9 fold compared to flat Pt and is compatible with the microfabrication technologies used to create flexible electrodes. These porous Pt electrodes show reduced thermal noise that matches theoretical predictions. In addition, we show that these electrodes can be implanted into rat cortex, record single unit activity, and be removed all without disrupting the integrity of the coating. We also demonstrate that the shape of the electrode (in addition to the surface area) has a significant effect on the electrode impedance when the feature sizes are on the order of tens of microns. SIGNIFICANCE: Overall, porous Pt represents a promising method for manufacturing low-impedance electrodes that can be seamlessly integrated into existing processes for producing flexible neural probes.

Indexed as

Cerebral CortexAnimalsElectric ImpedanceElectrodes, ImplantedMicroelectrodesPorosityRats

Identifiers

PMID32454468
PMCPMC7880536

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.