Evidence map›Paper›PMID 32453933›Full record

ArticleArchives of plastic surgery2020

The Exoscope versus operating microscope in microvascular surgery: A simulation non-inferiority trial.

Georgios Pafitanis, Michalis Hadjiandreou, Alexander Alamri, Christopher Uff, Daniel Walsh, Simon Myers

Open access · goldAbstract read
In one paragraph

Article in Archives of plastic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
8.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 56 citations in OpenAlex.

  1. Lymphovenous Bypass: Past, Present, and Future.Archives of plastic surgery · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. From Microscopic to Exoscopic Microsurgery: Are We Facing a Change of Paradigm?Advances and technical standards in neurosurgery · 2024
    Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Georgios PafitanisGroup for Academic Plastic Surgery, Microvascular Anastomosis Simulation Hub, The Blizard Institute, Queen Mary University of London, London, UK.
Michalis HadjiandreouBarts' and The London School of Medicine and Dentistry, London, UK.
Alexander AlamriDepartment of Neurosurgery, The Royal London Hospital, Barts Health NHS Trust, London, UK.
Christopher UffDepartment of Neurosurgery, The Royal London Hospital, Barts Health NHS Trust, London, UK.
Daniel WalshDepartment of Neurosurgery, King's College Hospital, London, UK.
Simon MyersGroup for Academic Plastic Surgery, Microvascular Anastomosis Simulation Hub, The Blizard Institute, Queen Mary University of London, London, UK.
Queen Mary University of London · GBBarts Health NHS Trust · GBKing's College Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Exoscope is a novel high-definition digital camera system. There is limited evidence signifying the use of exoscopic devices in microsurgery. This trial objectively assesses the effects of the use of the Exoscope as an alternative to the standard operating microscope (OM) on the performance of experts in a simulated microvascular anastomosis.

methodsModus V Exoscope and OM were used by expert microsurgeons to perform standardized tasks. Hand-motion analyzer measured the total pathlength (TP), total movements (TM), total time (TT), and quality of end-product anastomosis. A clinical margin of TT was performed to prove non-inferiority. An expert performed consecutive microvascular anastomoses to provide the exoscopic learning curve until reached plateau in TT.

resultsTen micro sutures and 10 anastomoses were performed. Analysis demonstrated statistically significant differences in performing micro sutures for TP, TM, and TT. There was statistical significance in TM and TT, however, marginal non-significant difference in TP regarding microvascular anastomoses performance. The intimal suture line analysis demonstrated no statistically significant differences. Non-inferiority results based on clinical inferiority margin (Δ) of TT=10 minutes demonstrated an absolute difference of 0.07 minutes between OM and Exoscope cohorts. A 51%, 58%, and 46% improvement or reduction was achieved in TT, TM, TP, respectively, during the exoscopic microvascular anastomosis learning curve.

conclusionsThis study demonstrated that experts' Exoscope anastomoses appear non-inferior to the OM anastomoses. Exoscopic microvascular anastomosis was more time consuming but end-product (patency) in not clinically inferior. Experts' "warm-up" learning curve is steep but swift and may prove to reach clinical equality.

Indexed as

ExoscopeMicroscopyMicrosurgeryMicrovascular anastomosisVideo telescope operating monitor

Identifiers

PMID32453933
PMCPMC7264907
OpenAlexW3026459395

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.