Evidence map›Paper›PMID 32453278›Full record

ArticleJournal of thoracic imaging2020

Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve.

Daniel Z Gordon, Muhannad A Abbasi, Jeesoo Lee, Roberto Sarnari, Alireza Sojoudi, Qiao Wei, Michael B Scott, Jeremy D Collins, Bradley D Allen, Julie A Blaisdell and 2 more

Abstract read
In one paragraph

Article in Journal of thoracic imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Daniel Z GordonDepartment of Radiology, Northwestern University, Chicago.
Muhannad A AbbasiDepartment of Radiology, Northwestern University, Chicago.
Jeesoo LeeDepartment of Radiology, Northwestern University, Chicago.
Roberto SarnariDepartment of Radiology, Northwestern University, Chicago.
Alireza SojoudiCircle Cardiovascular Imaging, Calgary, AB, Canada.
Qiao WeiCircle Cardiovascular Imaging, Calgary, AB, Canada.
Michael B ScottDepartment of Radiology, Northwestern University, Chicago.
Jeremy D CollinsDepartment of Radiology, Mayo Clinic, Rochester, MN.
Bradley D AllenDepartment of Radiology, Northwestern University, Chicago.
Julie A BlaisdellDepartment of Radiology, Northwestern University, Chicago.
James C CarrDepartment of Radiology, Northwestern University, Chicago.
Michael MarklDepartment of Radiology, Northwestern University, Chicago.

Funding

Northwestern University Clinical and Translational Science Institute (NUCATS)UL1TR001422 · NCATS · NORTHWESTERN UNIVERSITY AT CHICAGO · PI D'AQUILA, RICHARD · 2015 to 2023
$56.8M
Functional Cardiovascular 4D MRI in Congenital Heart DiseaseR01HL115828 · NHLBI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI MARKL, MICHAEL, RIGSBY, CYNTHIA K · 2012 to 2021
$5.2M
Evaluation of Aortic Hemodynamics and Compliance in Aortic StenosisF30HL145995 · NHLBI · NORTHWESTERN UNIVERSITY · PI SCOTT, MICHAEL BARAN · 2019 to 2022
$170k
NCATS NIH HHS UL1 TR001422NHLBI NIH HHS F30 HL145995NHLBI NIH HHS R01 HL115828
6 · The paper itself

Abstract

backgroundFour-dimensional (D) flow magnetic resonance imaging (MRI) is limited by time-consuming and nonstandardized data analysis. We aimed to test the efficiency and interobserver reproducibility of a dedicated 4D flow MRI analysis workflow. MATERIALS AND

methodsThirty retrospectively identified patients with bicuspid aortic valve (BAV, age=47.8±11.8 y, 9 male) and 30 healthy controls (age=48.8±12.5 y, 21 male) underwent Aortic 4D flow MRI using 1.5 and 3 T MRI systems. Two independent readers performed 4D flow analysis on a dedicated workstation including preprocessing, aorta segmentation, and placement of four 2D planes throughout the aorta for quantification of net flow, peak velocity, and regurgitant fraction. 3D flow visualization using streamlines was used to grade aortic valve outflow jets and extent of helical flow.

results4D flow analysis workflow time for both observers: 5.0±1.4 minutes per case (range=3 to 10 min). Valve outflow jets and flow derangement was visible in all 30 BAV patients (both observers). Net flow, peak velocity, and regurgitant fraction was significantly elevated in BAV patients compared with controls except for regurgitant fraction in plane 4 (91.1±29.7 vs. 62.6±19.6 mL/s, 37.1% difference; 121.7±49.7 vs. 90.9±26.4 cm/s, 28.9% difference; 9.3±10.1% vs. 2.0±3.4%, 128.0% difference, respectively; P<0.001). Excellent intraclass correlation coefficient agreement for net flow: 0.979, peak velocity: 0.931, and regurgitant fraction: 0.928.

conclusionOur study demonstrates the potential of an efficient data analysis workflow to perform standardized 4D flow MRI processing in under 10 minutes and with good-to-excellent reproducibility for flow and velocity quantification in the thoracic aorta.

Indexed as

Bicuspid Aortic Valve DiseaseHeart Valve DiseasesAdultAortic ValveBlood Flow VelocityHemodynamicsHumansImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedReproducibility of ResultsRetrospective Studies

Identifiers

PMID32453278
PMCPMC7680262

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.