The comparison of the process of manual and robotic positioning of the electrode performing radiofrequency ablation under the control of a surgical navigation system.
Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- Democratization in abdominal ablation therapies: The impact of percutaneous robotic assistance on accuracy-A systematic review.Journal of robotic surgery · 2025Pooled it
- Rapid Path Planning Algorithm for Percutaneous Rigid Needle Biopsy Based on Optical Illumination Principles.Sensors (Basel, Switzerland) · 2025Article
- Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024Article
- Article
- Assessment of experimental OpenCV tracking algorithms for ultrasound videos.Scientific reports · 2023Article
- Applications of Healthcare Robots in Combating the COVID-19 Pandemic.Applied bionics and biomechanics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study is aimed at the comparison of the process of manual and robotic positioning of the electrode performing radiofrequency ablation under the control of a surgical navigation system. The main hypothesis of this experiment was that the use of a collaborative manipulator (KUKA iiwa) will allow to position the active part of the electrode relative to the center of the tumor more accurately and from the first attempt. We also monitor the stability of the electrode's velocity during insertion and consider some advantages in ergonomics using the robotic manipulator. We use three more criteria to compare the surgeon's and robotic performance, unlike other studies, where only the target point's accuracy criterion is observed. The main idea is to examine the movement parameters of the electrode that can lead to potential patient trauma. Sphere-shaped tumor phantoms measuring 8 mm in diameter were filled with contrast and inserted in bovine livers. 10 livers were used for the robotic experiment and an equal quantity for manual surgery. The livers were encased in silicone phantoms designed to imitate the liver position in a real patient's abdominal cavity. Analysis of CT data gave the opportunity to find the entry and the target point for each tumor phantom. This data was loaded into a surgical navigation system that was used to track and record the position of the RF-electrode during the operation for further analysis. The standard deviation of points from the programmed linear trajectory totaled in the average 0.3 mm for the robotic experiment and 2.33 mm for the manual operation with a maximum deviation of 0.55 mm and 7.99 mm respectively. Standard deviation from the target point was 2.69 mm for the collaborative method and 2.49 mm for the manual method. The average velocity was 2.97 mm/s for the manipulator and 3.12 mm/s for the manual method, but the standard deviation of the velocity relative to the value of the average velocity was 0.66 mm/s and 3.05 mm/s respectively. Thus, in two criteria out of three, the manipulator is superior to the surgeon, and equality is established in one. Surgeons also noticed advantages in ergonomics performing the procedure using the manipulator. This experiment was produced as part of the work on the developing of a robotic multifunctional surgical complex. We can confirm the potential advantages of using collaborative robotic manipulators for minimally invasive surgery in case of practice for cancer treatment.