The comparison of the process of manual and robotic positioning of the electrode performing radiofrequency ablation under the control of a surgical navigation system.

A A Levin, D D Klimov, A A Nechunaev, A A Vorotnikov, L S Prokhorenko, E V Grigorieva, D A Astakhov, Y V Poduraev, D N Panchenkov

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

A A LevinMoscow State University of Technology "STANKIN", 1 Vadkovsky per., Moscow, 127055, Russian Federation. maverick@alexlevin.name.
D D KlimovMoscow State University of Technology "STANKIN", 1 Vadkovsky per., Moscow, 127055, Russian Federation.
A A NechunaevMoscow State University of Medicine and Dentistry named after A.I. Evdokimov, 20/1 Delegatskaya ul., Moscow, 127473, Russian Federation.
A A VorotnikovMoscow State University of Technology "STANKIN", 1 Vadkovsky per., Moscow, 127055, Russian Federation.
L S ProkhorenkoMoscow State University of Technology "STANKIN", 1 Vadkovsky per., Moscow, 127055, Russian Federation.
E V GrigorievaMoscow State University of Medicine and Dentistry named after A.I. Evdokimov, 20/1 Delegatskaya ul., Moscow, 127473, Russian Federation.
D A AstakhovMoscow State University of Medicine and Dentistry named after A.I. Evdokimov, 20/1 Delegatskaya ul., Moscow, 127473, Russian Federation.
Y V PoduraevMoscow State University of Technology "STANKIN", 1 Vadkovsky per., Moscow, 127055, Russian Federation.
D N PanchenkovMoscow State University of Medicine and Dentistry named after A.I. Evdokimov, 20/1 Delegatskaya ul., Moscow, 127473, Russian Federation.
Moscow State University of Medicine and Dentistry · RUMoscow State Technological University · RUUniversity of Technology · RULomonosov Moscow State University · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study is aimed at the comparison of the process of manual and robotic positioning of the electrode performing radiofrequency ablation under the control of a surgical navigation system. The main hypothesis of this experiment was that the use of a collaborative manipulator (KUKA iiwa) will allow to position the active part of the electrode relative to the center of the tumor more accurately and from the first attempt. We also monitor the stability of the electrode's velocity during insertion and consider some advantages in ergonomics using the robotic manipulator. We use three more criteria to compare the surgeon's and robotic performance, unlike other studies, where only the target point's accuracy criterion is observed. The main idea is to examine the movement parameters of the electrode that can lead to potential patient trauma. Sphere-shaped tumor phantoms measuring 8 mm in diameter were filled with contrast and inserted in bovine livers. 10 livers were used for the robotic experiment and an equal quantity for manual surgery. The livers were encased in silicone phantoms designed to imitate the liver position in a real patient's abdominal cavity. Analysis of CT data gave the opportunity to find the entry and the target point for each tumor phantom. This data was loaded into a surgical navigation system that was used to track and record the position of the RF-electrode during the operation for further analysis. The standard deviation of points from the programmed linear trajectory totaled in the average 0.3 mm for the robotic experiment and 2.33 mm for the manual operation with a maximum deviation of 0.55 mm and 7.99 mm respectively. Standard deviation from the target point was 2.69 mm for the collaborative method and 2.49 mm for the manual method. The average velocity was 2.97 mm/s for the manipulator and 3.12 mm/s for the manual method, but the standard deviation of the velocity relative to the value of the average velocity was 0.66 mm/s and 3.05 mm/s respectively. Thus, in two criteria out of three, the manipulator is superior to the surgeon, and equality is established in one. Surgeons also noticed advantages in ergonomics performing the procedure using the manipulator. This experiment was produced as part of the work on the developing of a robotic multifunctional surgical complex. We can confirm the potential advantages of using collaborative robotic manipulators for minimally invasive surgery in case of practice for cancer treatment.

Identifiers

PMID32451395
PMCPMC7248067
OpenAlexW3028578893

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.