Evidence map›Paper›PMID 32449031›Full record

SynthesisUpdates in surgery2020

Use of machine perfusion in livers showing steatosis prior to transplantation: a systematic review.

Quirino Lai, Franco Ruberto, Timothy M Pawlik, Francesco Pugliese, Massimo Rossi

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Updates in surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. [Amatoxin poisoning with acute liver failure].Chirurgie (Heidelberg, Germany) · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Normothermic Machine Perfusion-Improving the Supply of Transplantable Livers for High-Risk Recipients.Transplant international : official journal of the European Society for Organ Transplantation · 2022
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Quirino LaiDepartment of General Surgery and Organ Transplantation, Sapienza University of Rome, Viale del Policlinico 155, 00161, Rome, Italy. lai.quirino@libero.it.ORCID http://orcid.org/0000-0003-1487-3235
Franco RubertoDepartment of Anaesthesiology, Critical Care Medicine and Pain Therapy, Sapienza University of Rome, Rome, Italy.
Timothy M PawlikThe Ohio State University Wexner Medical Center, Columbus, OH, USA.
Francesco PuglieseDepartment of Anaesthesiology, Critical Care Medicine and Pain Therapy, Sapienza University of Rome, Rome, Italy.
Massimo RossiDepartment of General Surgery and Organ Transplantation, Sapienza University of Rome, Viale del Policlinico 155, 00161, Rome, Italy.
Policlinico Umberto I · ITSapienza University of Rome · ITThe Ohio State University Wexner Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe role of machine perfusion (MP) in the evaluation of liver grafts with macrovesicular steatosis (MaS) remains ill-defined as only a limited number of studies has been reported. The objective of the current study was to provide a systematic review to evaluate the role of MP in the setting of MaS livers.

methodsA systematic review, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines was performed. Eligible articles published up to April 2019 were included using the MEDLINE, Scopus, and Google Scholar databases.

resultsAmong the 422 articles screened, only 16 papers met the inclusion criteria. A total of 54 cases of MP use before liver transplantation were included. Sixteen (29.6%) grafts were from donors after circulatory death. In 22 (40.7%) cases, hypothermic machine perfusion was performed. Normothermic machine perfusion was done in the remaining 32 (59.3%) cases. According to the histological results of the donor core biopsy, a MaS value < 30% was observed in 41 (75.9%) cases, whereas 13 (24.1%) patients had moderate-to-severe (≥ 30%) MaS. Following categorization of the pooled population according to the presence of moderate-to-severe (≥ 30%) MaS in the donor graft, no differences were noted in terms of post-transplant death or severe complications following MP. There was no correlation between the proportion of MaS in the donor graft relative to post-transplant peak ALT among patients treated with MP. Among the entire pooled cohort, there was also no correlation between MaS values and ALT peak (R = 0.13; P = 0.42).

conclusionsMP appears to be feasible and safe in MaS livers. Experience to date has been very limited, and the benefit of MP remains not determined. Prospective studies will need to define better the potential effect of "defatting" drugs used during the perfusion process on MaS.

Indexed as

Fatty LiverTissue DonorsAlanine TransaminaseBiomarkersHumansLiver TransplantationOrgan PreservationPerfusionSafetyTransplantsAlanine TransaminaseBiomarkersDefattingHOPEHypothermic machine perfusionNormothermic machine perfusionOutcomesPrimary-non-function

Identifiers

PMID32449031
OpenAlexW3027151018

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.