Evidence map›Paper›PMID 32449028›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2021

Sound-localisation performance in patients with congenital unilateral microtia and atresia fitted with an active middle ear implant.

Chunli Zhao, Yujie Liu, Jinsong Yang, Peiwei Chen, Mengdie Gao, Shouqin Zhao

Abstract read
PubMed Publisher
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.

  1. Efficacy of vibrant sound bridge in congenital aural atresia: an updated systematic review.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Pooled it
  2. Implantable hearing devices in clinical practice. Systematic review and consensus statements.Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale · 2024
    Pooled it
  3. Long-term safety and subjective satisfaction of Bonebridge and Vibrant Soundbridge in congenital unilateral conductive hearing loss.Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale · 2024
    Article
  4. Article
  5. Article
  6. Audiological and subjective benefit with a new adhesive bone conduction hearing aid in children with congenital unilateral microtia and atresia.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022
    Article
  7. Article
  8. Observational
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Chunli ZhaoDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Yujie LiuDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Jinsong YangDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Peiwei ChenDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Mengdie GaoDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Shouqin ZhaoDepartment of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. shouqinzhao@163.com.ORCID http://orcid.org/0000-0001-5974-2701
Beijing Tongren Hospital · CN

Funding

National Natural Science Foundation of China 81770989Project of Capital Clinical Characteristic Application Research of Beijing Municipal Science and Technology Commission Z171100001017079
6 · The paper itself

Abstract

objectiveThis study assessed the safety and sound-localisation ability of the Vibrant Soundbridge (VSB) (Med-EL, Innsbruck, Austria) in patients with unilateral microtia and atresia (MA).

methodsThis was a single-centre retrospective research study. Twelve subjects with unilateral conductive hearing loss (UCHL) caused by ipsilateral MA were recruited, each of whom underwent VSB implantation and auricular reconstruction. The bone-conduction (BC) threshold was measured postoperatively, and the accuracy of sound localisation was evaluated at least 6 months after surgery. Horizontal sound-localisation performance was investigated with the VSB activated and inactivated, at varying sound stimuli levels (65, 70 and 75 dB SPL). Localisation benefit was analysed via the mean absolute error (MAE).

resultsThere was no statistical difference in mean BC threshold of impaired ears measured preoperatively and postoperatively. When compared with VSB-inactivated condition, the MAE increased significantly in unilateral MA patients in the VSB-activated condition. Besides, sound-localisation performance worsened remarkably when sound was presented at 70 dB SPL and 75 dB SPL. Regarding the side of signal location, the average MAE with the VSB device was much higher than that without the VSB when sound was from the normal-hearing ear. However, no significant difference was observed when sound was located from the impaired ear.

conclusionThis study demonstrates that in patients with unilateral MA, the VSB device does not affect inner-ear function. Sound-localisation ability is not improved, but deteriorated at follow-up. Our results suggest that the VSB-aided localisation abilities may be related to the thresholds between the ears, plasticity of auditory system and duration of use of VSB.

Indexed as

Hearing AidsOssicular ProsthesisSound LocalizationAdolescentAustriaCongenital MicrotiaFemaleHearing Loss, ConductiveHumansMaleRetrospective StudiesTreatment OutcomeYoung AdultConductiveHearing loss, unilateralMicrotia and atresiaSound localisationVibrant soundbridge

Identifiers

PMID32449028
OpenAlexW3026450307

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.