Evidence map›Paper›PMID 32448232›Full record

Observational studyBMC ophthalmology2020

Interobserver reproducibility and interocular symmetry of the macular ganglion cell complex: assessment in healthy children using optical coherence tomography.

Alicia Muñoz-Gallego, Javier De la Cruz, Martín Rodríguez-Salgado, José L Torres-Peña, Javier Sambricio, Ana Ortueta-Olartecoechea, Pilar Tejada-Palacios

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in BMC ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Optic disc morphology and interocular symmetry in children.Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Alicia Muñoz-GallegoOphthalmology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Javier De la CruzHospital Universitario 12 de Octubre, Healthcare Research Institute (IMAS12), Servicio Madrileño de Salud (SERMAS-H12O), CAA-6D. Avda. de Códoba s/n, E-28041, Madrid, Spain. javier.delacruz@salud.madrid.org.
Martín Rodríguez-SalgadoServicio Madrileño de Salud (SERMAS), Primary Health Care, Madrid, Spain.
José L Torres-PeñaOphthalmology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Javier SambricioOphthalmology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Ana Ortueta-OlartecoecheaOphthalmology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Pilar Tejada-PalaciosOphthalmology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Hospital Universitario 12 De Octubre · ESMadrid Health Service · ESUniversidad Complutense de Madrid · ES

Funding

Instituto de Salud Carlos III (ES) PI 17/01073
6 · The paper itself

Abstract

backgroundAssessment of interobserver reproducibility and interocular symmetry using optical coherence tomography (OCT)-based measurements of the macular ganglion cell complex (GCC) in healthy children facilitates interpretation of OCT data. We assessed the interobserver reproducibility and interocular symmetry of GCC and evaluated candidate determinants.

methodsThis was a cross-sectional study performed in a primary and tertiary health-care setting. A total of 126 healthy participants aged 5 to 18 years were eligible. GCC scans were performed by 4 operators using the Topcon 3D OCT-2000 device. Intraclass correlation coefficients (ICCs) were used to estimate reproducibility and symmetry. Cut-off points for symmetry were defined as the 95th percentile of the absolute interocular difference for 6 GCC parameters. Percentile distributions of interocular difference were generated based on age and difference in absolute interocular spherical equivalent (SE).

resultsThe reproducibility ICC ranged from 0.96 to 0.98 for all 6 GCC parameters. Cut-off points for interocular symmetry of the superior and inferior quadrants and total macular retinal nerve fibre layer thickness (mRNFL) and macular ganglion cell layer-inner plexiform layer thickness were 3.5, 4.5, 3.0, 3.0, 2.5, and 2.5 μm respectively. A positive association was observed between the absolute interocular difference of SE and superior and total mRNFL symmetry values (p = 0.047 and p = 0.040, respectively).

conclusionsOCT measurements of GCC in healthy children show excellent reproducibility. Interocular differences in SE should be assessed when mRNFL differences exceed the 95% cut-off. These findings can contribute to establish reference values for interocular symmetry in paediatric GCC parameters.

Indexed as

AdolescentChildChild, PreschoolCross-Sectional StudiesFemaleHumansMacula LuteaMaleNerve FibersObserver VariationReference ValuesReproducibility of ResultsRetinal Ganglion CellsTomography, Optical CoherenceChildhoodGanglion cell complexInterobserver reproducibilityInterocular symmetryMacular ganglion cell-inner plexiform layerMacular retinal nerve fibre layerOptical coherence tomographyPaediatric reference databaseReproducibilityRetinal ganglion cellsSymmetry

Identifiers

PMID32448232
PMCPMC7245936
OpenAlexW3028541650

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.