Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9601T.

Mitsuo Kuwabara, Kanako Harada, Yukiko Hishiki, Takayoshi Ohkubo, Kazuomi Kario, Yutaka Imai

Open access · bronzeAbstract read
In one paragraph

Article in Journal of clinical hypertension (Greenwich, Conn.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
3.4field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 34 citations in OpenAlex.

  1. Trial
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Review
  7. Article
  8. Benefit of wearable blood pressure monitoring device in Society 5.0.Hypertension research : official journal of the Japanese Society of Hypertension · 2022
    Article
  9. Article
  10. Article
  11. Review
  12. Accurate nighttime blood pressure monitoring with less sleep disturbance.Hypertension research : official journal of the Japanese Society of Hypertension · 2021
    Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Mitsuo KuwabaraDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.ORCID 0000-0003-2727-1575
Kanako HaradaOmron Healthcare Co., Ltd, Kyoto, Japan.
Yukiko HishikiOmron Healthcare Co., Ltd, Kyoto, Japan.
Takayoshi OhkuboDepartment of Hygiene and Public Health, Teikyo University School of Medicine, Tokyo, Japan.ORCID 0000-0002-3283-8196
Kazuomi KarioDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.ORCID 0000-0002-8251-4480
Yutaka ImaiTohoku Institute for Management of Blood Pressure, Sendai, Japan.
Omron (Japan) · JPJichi Medical University · JPTeikyo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to validate the accuracy of the Omron HEM-9601T, an automatic wrist-type device for self-blood pressure (BP) measurement with a timer function for automatic measurement of nocturnal BP, in the sitting position according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 guidelines, and to assess its performance in the supine position by applying the same protocol as conducted in the sitting position. The mean differences between the reference BPs and HEM-9601T readings were 1.2 ± 6.9/1.1 ± 5.5 mmHg, 2.2 ± 6.5/1.8 ± 5.7 mmHg, 0.1 ± 6.6/1.5 ± 6.2 mmHg, and -0.8 ± 7.2/0.5 ± 6.4 mmHg for systolic BP/diastolic BP for criterion 1 in the sitting position, supine with sideways palm position, supine with upward palm position, and supine with downward palm position, respectively. In addition, the mean differences and their standard deviations for systolic BP and diastolic BP calculated according to criterion 2 in the ANSI/AAMI/ISO 81060-2:2013 guidelines were acceptable in all four positions. In conclusion, the Omron HEM-9601T fulfilled the validation criteria of the ANSI/AAMI/ISO81060-2:2013 guidelines when used in the sitting position with the wrist at heart level, and its accuracy in the supine position was acceptable and roughly equivalent to that in the sitting position. The wrist-type home BP monitor could be a more suitable tool for repeated nocturnal BP measurements at home than upper-arm devices, and could improve the reliability of diagnosis and management of nocturnal hypertension.

Indexed as

Blood Pressure MonitorsHypertensionBlood Pressure DeterminationFemaleHumansMaleMiddle AgedPractice Guidelines as TopicReproducibility of ResultsSitting PositionSupine PositionWristANSI/AAMI/ISO81060-2:2013blood pressurehome nocturnal blood pressureself-measurementvalidationwrist-type blood pressure monitor

Identifiers

PMID32447831
PMCPMC7383585
OpenAlexW3027402579

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.