ArticleJournal of vascular surgery2021
Patient Safety Indicators are an insufficient performance metric to track and grade outcomes of open aortic repair.
Article in Journal of vascular surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- The role of early venous duplex screening in improving patient safety indicator-12 (PSI-12) classification accuracy: a retrospective cohort study.Patient safety in surgery · 2026Article
- Midterm outcomes of isolated thoracic aortic replacement in congenital versus degenerative aortopathy in a 15-year institutional cohort.Journal of vascular surgery · 2023Article
- Connective tissue disease type mediates branch patency of grafts in open thoracoabdominal aortic reconstruction.Journal of vascular surgery · 2022Article
- Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair.Journal of vascular surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
objectiveNational rankings of hospitals rely on outcomes-based evaluation to assess the performance of surgical programs, particularly those performing high-risk elective surgical procedures such as open aortic repair. Various classification systems exist for tracking outcomes, but increasingly the International Classification of Diseases, Tenth Revision-based Agency for Healthcare Research and Quality Patient Safety Indicators (PSIs) are used as a publicly reported comparison measure of hospital quality performance. We sought to critically evaluate the accuracy of the existing vehicles to assess open aortic repair outcomes in an established program.
methodsThis is a case-control study of patients who underwent open abdominal aortic aneurysm repair at the Johns Hopkins Medical Institutions from 2004 to 2018. Patients' characteristics and outcomes were collected as part of a prospectively maintained retrospective database. For each case, hemorrhagic, cardiac, respiratory, renal, wound, and thromboembolic complications were identified with the unique definitions used for open abdominal aortic aneurysm repair by the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database, the Society for Vascular Surgery Vascular Quality Initiative (VQI) database, and the Agency for Healthcare Research and Quality PSI initiative.
resultsOf the 154 patients included in the study, 79 (51.0%) were identified as having a complication as defined by the VQI, 46 (29.7%) according to the NSQIP, and 15 (9.7%) according to the PSI system (P < .001). Patients most likely to incur a complication in the PSI system were those with a pararenal or more extensive aneurysm, with baseline congestive heart failure, requiring a supramesenteric clamp (all P < .01), or with an aneurysm >6.5 cm in diameter (P = .02). The NSQIP and VQI systems both identified more postoperative hemorrhagic, respiratory, renal, and wound complications than the PSI system did (P < .05). The VQI system identified the most renal complications (52; P < .001); factors unique to incurring a complication in the VQI include use of a suprarenal clamp and performance of an aortorenal bypass procedure as part of the repair (P < .01). Particularly weak correlation was noted between the PSI system and the VQI with respect to renal outcomes (ρ = 0.163).
conclusionsThe PSI system identified fewer important complications than either of the clinically focused databases, with the VQI capturing the most postoperative events, mostly because of its stringent definition of renal injury. We conclude that the PSI system should not form the basis of grading hospital performance in comparing clinically relevant complications of open aortic surgery programs.
Indexed as