Evidence map›Paper›PMID 32442611›Full record

ArticleJournal of vascular surgery2021

Patient Safety Indicators are an insufficient performance metric to track and grade outcomes of open aortic repair.

Rebecca Sorber, Katherine A Giuliano, Caitlin W Hicks, James H Black

Abstract read
In one paragraph

Article in Journal of vascular surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Rebecca SorberDepartment of Vascular Surgery and Endovascular Therapy, Johns Hopkins Medical Institutions, Baltimore, Md. Electronic address: rsorber1@jhmi.edu.
Katherine A GiulianoDepartment of Vascular Surgery and Endovascular Therapy, Johns Hopkins Medical Institutions, Baltimore, Md.
Caitlin W HicksDepartment of Vascular Surgery and Endovascular Therapy, Johns Hopkins Medical Institutions, Baltimore, Md; Johns Hopkins Surgery Center for Outcomes Research, The Johns Hopkins Hospital, Baltimore, Md.
James H BlackDepartment of Vascular Surgery and Endovascular Therapy, Johns Hopkins Medical Institutions, Baltimore, Md.

Funding

Risk Factors and Outcomes Associated with Late-Life Diabetic Peripheral NeuropathyK23DK124515 · NIDDK · JOHNS HOPKINS UNIVERSITY · PI HICKS, CAITLIN WHITNEY · 2020 to 2024
$898k
NIDDK NIH HHS K23 DK124515
6 · The paper itself

Abstract

objectiveNational rankings of hospitals rely on outcomes-based evaluation to assess the performance of surgical programs, particularly those performing high-risk elective surgical procedures such as open aortic repair. Various classification systems exist for tracking outcomes, but increasingly the International Classification of Diseases, Tenth Revision-based Agency for Healthcare Research and Quality Patient Safety Indicators (PSIs) are used as a publicly reported comparison measure of hospital quality performance. We sought to critically evaluate the accuracy of the existing vehicles to assess open aortic repair outcomes in an established program.

methodsThis is a case-control study of patients who underwent open abdominal aortic aneurysm repair at the Johns Hopkins Medical Institutions from 2004 to 2018. Patients' characteristics and outcomes were collected as part of a prospectively maintained retrospective database. For each case, hemorrhagic, cardiac, respiratory, renal, wound, and thromboembolic complications were identified with the unique definitions used for open abdominal aortic aneurysm repair by the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database, the Society for Vascular Surgery Vascular Quality Initiative (VQI) database, and the Agency for Healthcare Research and Quality PSI initiative.

resultsOf the 154 patients included in the study, 79 (51.0%) were identified as having a complication as defined by the VQI, 46 (29.7%) according to the NSQIP, and 15 (9.7%) according to the PSI system (P < .001). Patients most likely to incur a complication in the PSI system were those with a pararenal or more extensive aneurysm, with baseline congestive heart failure, requiring a supramesenteric clamp (all P < .01), or with an aneurysm >6.5 cm in diameter (P = .02). The NSQIP and VQI systems both identified more postoperative hemorrhagic, respiratory, renal, and wound complications than the PSI system did (P < .05). The VQI system identified the most renal complications (52; P < .001); factors unique to incurring a complication in the VQI include use of a suprarenal clamp and performance of an aortorenal bypass procedure as part of the repair (P < .01). Particularly weak correlation was noted between the PSI system and the VQI with respect to renal outcomes (ρ = 0.163).

conclusionsThe PSI system identified fewer important complications than either of the clinically focused databases, with the VQI capturing the most postoperative events, mostly because of its stringent definition of renal injury. We conclude that the PSI system should not form the basis of grading hospital performance in comparing clinically relevant complications of open aortic surgery programs.

Indexed as

Patient SafetyAgedAortic Aneurysm, AbdominalFemaleHumansMaleQuality Indicators, Health CareRetrospective StudiesRisk AssessmentVascular Surgical ProceduresCare regionalizationOpen aortic repair outcomesPatient Safety IndicatorsPSIPSI-90

Identifiers

PMID32442611
PMCPMC7721207

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.