Evidence map›Paper›PMID 32440863›Full record

ArticleAnalytical and bioanalytical chemistry2020

A single-cell identification and capture chip for automatically and rapidly determining hydraulic permeability of cells.

Yeye Xu, Weiping Ding, Shibo Li, Chengpan Li, Dayong Gao, Bensheng Qiu

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Passive coupling of membrane tension and cell volume during active response of cells to osmosis.Proceedings of the National Academy of Sciences of the United States of America · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Yeye XuCenter for Biomedical Engineering, University of Science and Technology of China, Hefei, 230027, Anhui, China.
Weiping DingCenter for Biomedical Engineering, University of Science and Technology of China, Hefei, 230027, Anhui, China. wpdings@ustc.edu.cn.
Shibo LiCenter for Biomedical Engineering, University of Science and Technology of China, Hefei, 230027, Anhui, China.
Chengpan LiCenter for Biomedical Engineering, University of Science and Technology of China, Hefei, 230027, Anhui, China.
Dayong GaoDepartment of Mechanical Engineering, University of Washington, Seattle, WA, 98195, USA.
Bensheng QiuCenter for Biomedical Engineering, University of Science and Technology of China, Hefei, 230027, Anhui, China.
University of Science and Technology of China · CNUniversity of Washington · US

Funding

National Natural Science Foundation of China 81627806
6 · The paper itself

Abstract

The hydraulic permeability of the lipid bilayer membrane of a single cell, a very important parameter in biological and medical fields, has been attracting increasing attention. To date, methods developed to determine this permeability are either operation-complicated or time-consuming. Therefore, we developed a chip for automatically and rapidly determining the permeability of cells that integrates microfluidics and cell impedance analysis. The chip is designed to automatically identify a single cell, capture the cell, and record the volume change in that cell. We confirmed the abilities of single-cell identification and capture with the upper and lower voltage thresholds determined, validated the performance of the differential electrode design for accurate cell volume measurements, deduced the extracellular osmotic pressure change in the presence of a hypertonic solution according to fluorescence intensity, and demonstrated the single-cell volume change recorded by the chip. Then, the accuracy of the permeability determined with the chip was verified using HeLa cells. Finally, the permeability of human-induced pluripotent stem cells (hiPSCs) was determined to be 0.47 ± 0.03 μm/atm/min. Using the chip, the permeability can be determined within 5 min. This study provides insights for the new design of an automatic single-cell identification and capture chip for single cell-related studies. Graphical abstract.

Indexed as

Cell Membrane PermeabilityCell SizeLab-On-A-Chip DevicesCell LineElectric ImpedanceEquipment DesignHeLa CellsHumansInduced Pluripotent Stem CellsMicrofluidic Analytical TechniquesSingle-Cell AnalysisCell impedancehiPSCHydraulic permeabilityMicrofluidicsSingle-cell captureSingle-cell identification

Identifiers

PMID32440863
OpenAlexW3027337788

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.